User manual

V Panel 104 / 121 / 150 / 170 / 190 User Manual
14
© Copyright Kontron Embedded Computers GmbH
3.3.11 Communication port to touchcontroller SW3
ON
1
OFF
Setting SW3 DIP1 Communication port COM
OFF COM1
ON COM4
3.3.12 Touch wire configurationr SW3
ON
1
OFF
Setting SW3 DIP2 Touchtype
OFF 5 wire
ON 4 wire
3.3.13 Output configuration USB Port 0 SW4
ON
1
OFF
Setting SW4 DIP1 USB Port 0
OFF (default) External Connector J22
ON Internal Connector J31
3.3.14 Output configuration USB Port I SW4
Setting SW4 DIP2 USB Port 1
OFF (default) External Connector J22
ON Internal Connector J31
3.4 LED STATUS INDICATORS
3.3.1 Power LED D16 bottom
Description ON green OFF
POWER POWER OK No power
3.3.2 HDD LED D16 top
Description ON red OFF
HDD activity Datatranfer from/to HDD No access
3.3.3 Fieldbus status
Status including possible fieldbus modules
Baseboard LED D18 CanOpen and
Profibus Module
DeviceNet
Module
Indicated Status
Top Ready
(yellow)
Bottom
RUN
(green)
ERROR
D1
Status
D2
ERROR
D3
Flashing
irregular
OFF OFF OFF OFF Fieldbus hardware error
Flashing
cyclic
OFF OFF OFF OFF Bootstraploader active
ON
Flashing
irregular
OFF OFF RED No slave or fieldbus not connected
ON
Flashing
cyclic
OFF ON - PC applikation not redy
ON
Flashing
cyclic
ON
OFF - Short circuite at fieldbus
ON
Flashing
cyclic
ON
ON RED No slave or fielbus not connected
ON ON ON
ON RED At least one slave is missing
ON ON
OFF ON GREEN Communication is running faultless