Contents Contents Introduction.......................................................................................................... 3 Symbols used in this Manual ................................................................................. 4 Important Instructions......................................................................................... 5 Note on the Warranty.............................................................................................
Contents Monitor Connecting and Turning On ...............................................................27 Touchscreen Software Installation .......................................................................28 Selecting the Touchscreen Controller..............................................................28 Calibrating the Touchscreen............................................................................30 Maintenance and Prevention .............................................................
Introduction Introduction Kontron Embedded Computers would like to point out that the information contained in this manual may be subject to technical changes, particularly as a result of continuous product upgrades. The attached documentation does not entail any guarantee on the part of Kontron Embedded Computers with respect to technical processes described in the manual or any product characteristics set out in the manual.
Introduction Symbols used in this Manual Symbol Meaning This symbol indicates the danger of injury to the user or the risk of damage to the product if the corresponding warning notices are not observed. This symbol indicates that the product or parts thereof may be damaged if the corresponding warning notices are not observed. This symbol indicates general information about the product and the user manual. This symbol precedes helpful hints and tips for daily use.
Important Instructions Important Instructions This chapter contains instructions which must be observed when using your industrial LCD monitor KFM19_e. The manufacturer’s instructions provide useful information on your industrial LCD monitor KFM19_e. Note on the Warranty Due to their limited service life, parts which, by their nature, are especially subject to wear (wearing parts) are not included in the guarantee beyond the legal stipulations. This applies to the display backlighting, for example.
Safety Instructions Safety Instructions Please read this section carefully and observe the instructions for your own safety and correct use of the device. This chapter also contains information on approval and interference suppression of your device. Please observe the warnings and instructions on the device and in the manual. The industrial LCD monitor KFM19_e has been built and tested by Kontron Embedded Computers in accordance with EN 60950/VDE 0805 and left the company in a perfectly safe condition.
Safety Instructions ❏ Only devices and components which fulfill the requirements of a SELV circuit (Safety Extra Low Voltage) in accordance with EN 60950 may be connected to the interfaces of the system. ❏ All plugs on the connection cables must be screwed or locked to the housing. ❏ The device is designed to be used in vertical position. ❏ Repairs may only be carried out by a person authorized by Kontron Embedded Computers.
Safety Instructions FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in commercial environment.
Scope of Delivery Scope of Delivery ❏ Industrial LCD monitor KFM19_e (A or B) ❏ This user manual for the industrial LCD monitor KFM19_e ❏ KFM - OSD-Menu - Description ❏ AC power cord or DC Phoenix plug (depending on the ordered KFM19_e) ❏ VGA cable connector (2 m) ❏ 8x M4 nuts (for panelmount version only) Optional Parts ❏ USB or serial (COM) touchscreen cable connector depending on the ordered touchscreen terminal configuration (optional) Available lengths for: USB cable connector (Type A, male - Type A,
Product Description Product Description The KFM19_e is an industrial LCD monitor designed for high-performance industrial applications. The solid type of enclosure offers to the monitor a mechanical stability. KFM19_e is therefore proper for industrial use. Excellent image representation, simple menu-driven handling and plug & play ability round off the qualities of this monitor. The built-in display is a 19" TFT SXGA display with 1280 x 1024 resolution and 2 300 cd/m luminance (brightness).
Product Description Front Panel The front plate of the KFM19_e is available alternatively as 19" front plate or in panelmount version. The 19" front plate version is suitable for the installation of the monitor in 19" industrial cabinets. Therefore are available four mounting holes. The panelmount version is suitable for the installation of the monitor in an instrument panel or other cabinets. Therefore at the rear side of the front plate are available eight threaded studs.
Product Description Display The built-in display is a 19" TFT SXGA display with a resolution of 1280 x 1024 2 and 300 cd/m of luminance (brightness). In front of the display is installed a glass protection pane with antireflection properties. This protects the display surface from dirt and scratches also. The technical specifications of the built-in display are specified in the “Technical Data” chapter. Display with Touchscreen The KFM19_e can be optionally equipped with a resistive touchscreen.
Product Description Controls and LED Indicator At the front plate are situated the control buttons of the On Screen Display (OSD), the “On/Off” button and the “Status LED”. The keys of the OSD and the “On/Off” button can be optionally attached to the right side (rear-mounted) of the monitor (refer to Fig. 3a). For this device configuration the “Status LED” is installed at the front side. Fig. 3: KFM_19e – Controls and LED indicator at the front side installed controls 2 1 3 4 Fig.
Product Description “On/Off” Button and Status LED “On/Off” Button Press this button, in order to switch on or off the monitor KFM19_e. Even if you switch the monitor off with the “On/Off” button, a standby voltage is further present in the device. The unit is complete disconnected from the power source, only when the power cord is disconnected from the power source. Therefore the power cord and its connectors must always remain easily accessible.
Product Description Left Side The interfaces and the power plug (AC or DC) are located at the left side of the monitor. 1 2 3 4 5 6 Fig. 5: KFM19_e Fig.
Product Description Interfaces The following interfaces with standard pin assignments are available: ❏ VGA (analog) input ❏ DVI-D (digital) input ❏ S-Video (analog) input ❏ C-Video (Composite Video) (analog) input ❏ USB / COM interface as the touchscreen terminal You can connect one corresponding signal source to each video interface at the same time. By means of the OSD Menu function “Select” you can select which of the signal source shall be represented on the display.
Product Description S-Video Input The S-Video input is a 4 pin Mini DIN connector (female), and allows you to connect external analog signal sources as e.g. DVD or video player. The industrial LCD monitor KFM19_e supports at this interface TV pictures format PAL (768 x 576), NTSC (640 x 480) and SECAM. Composite-Video Input The Composite-Video input is a cinch connector (yellow, female), and allows you to connect external analog signal sources as e.g. DVD or video player.
Product Description Rear Side At the rear side of the KFM19_e are the threaded studs (available only at panelmount front plate version) and the rubber seal. 1 2 1 1 1 Fig. 6: Rear side of the KFM19_e (shown as panelmount front plate version) 18 1 Threaded studs metric (available only at panelmount front plate version) 2 Rubber seal 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Product Description Air Openings Behind the front plate, at the housings upper and bottom side are the air openings. Fig. 7: Air openings (top side) Fig. 8: Air openings (bottom side) When installing and switching on the monitor, make sure that the air openings at the bottom and upper side of the device (behind the front panel) are not obstructed by objects. 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Product Description On Screen Display (OSD) Over the On Screen Display (OSD) can be installed the features, as OSD position and time, brightness, contrast, color, sharpness and others. Some of these menus have sub-menus. The push buttons allow you to select, to scroll, to install in the OSD main menu or OSD-submenu. Operation of the OSD Menu 1. Press
Product Description Power Supply The KFM19_e can be optionally equipped with an AC PSU or a DC PSU. The supply voltage range is indicated on the type label. The type label is located on the rear of the unit. System Version Integrated PSU Input KFM19_e - A AC Power Supply 100 - 240 VAC 50 - 60 Hz max. 0.6 A KFM19_e - B DC Power Supply 20 - 34 VDC max. 2.
Product Description AC Connection AC-power plug Fig. 9: AC power plug 1. Connect the supplied AC power cord into the system AC power plug. 2. Connect the other end of the AC power cord into a corresponding outlet. Use the power cord suitable for the power supply in your country. Do not remove or alter the grounding prong on the power cord. In situations where a two-slot receptacle is present, have it replaced with a properly grounded three-prong grounding type receptacle.
Product Description DC Connection For the DC connection prepare the connecting wires using the supplied Phoenix plug terminal. The length of the DC connecting wires may not exceed 10 m. DC Phoenix connector with plug terminal DC Phoenix connector – – + + Fig. 10: DC Phoenix connector Fig. 10a: DC Phoenix connector with plug terminal (supplied) 1. Cut the required length of two isolated wires (∅ up to 1.5 mm ). 2 2. Strip each end 5 –7 mm. 3. Twist the striped wire ends and tin it with solder.
Product Description 4. Loosen the two slotted pan head screws of the DC plug terminal far enough so that you can insert the end of the power cord. 1 2 3 4 Fig. 11: Phoenix plug terminal with positive and negative voltage wire (example) 1 Phoenix plug terminal 3 Negative voltage wire (black) 2 Slotted pan head screws 4 Positive voltage wire (red) 5. Insert the negative and positive voltage wire into the corresponding clamp of the Phoenix plug terminal.
Installation Instructions Installation Instructions Please observe the described hints in the “Safety Instructions” chapter and the specification listed in the “Technical Data” chapter. Instruction for Mounting Please take into consideration the needed free space on the interface side, before you install the monitor into an industrial cabinet, an instrument panel or other cabinets. For detailed information about the available interfaces refer to the section “Interfaces”.
Installation Instructions Panelmount Version If you install the panel version of the KFM19_e into an instrument panel or other cabinets, use the eight threaded M4 metric studs on the rear side of the front plate. For the panel assembly cut a window and pre-drill holes according Fig. 12. The monitor must be attached firmly with eight M4 metric nuts. ∅7 (8x) The contact surface with the rubber seal must be clean and flush. Fig.
Monitor Connecting and Turning On Monitor Connecting and Turning On The industrial LCD monitor KFM19_e can be connected to IBM PC systems equipped with corresponding graphics capability. 1. Connect the PC system’s video signal output interface to the video signal input of the KFM19_e using the supplied video signal cable (depending on your ordering). 2.
Monitor Connecting and Turning On Touchscreen Software Installation The driver for Windows® 2000 / XP operating system for the touchscreen installation is included on the CD-ROM supplied. Insert the CD-ROM, double-click on “setup.exe” to start the installer. During the installation sequence, some screens will appear (“Welcome”, “Select Folder”, “Select Destination Directory”, “Number of devices”).
Monitor Connecting and Turning On If you choose [DMC TSC-10 Series, Serial], the “Serial port” setting window appears. Choose the corresponding port from popup menu. Fig. 14: Selection of the corresponding port After installing the touchscreen driver, be sure to restart your computer to load and activate the touchscreen driver. Afterwards the calibration of the touchscreen has to be carried out. 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Monitor Connecting and Turning On Calibrating the Touchscreen After the installation of the touchscreen driver, you have to calibrate the touchscreen. The calibration serves two purposes: ❏ Sets the active area of the touchscreen. ❏ Aligns the active area of the touchscreen to the screen’s image. Before you calibrate the touchscreen, let the KFM19_e warm up for 30 minutes. Do not use a hard or a pointed object to operate the touchscreen, since it can damage the touchscreen surface.
Monitor Connecting and Turning On You can adjust the calibration of the touchscreen by running the program at [Start] → [Program] → [UPDD] → [Control setting]. Use your finger to touch the crosshair on the light gray screen. Touching the crosshair lets it appear at another position. Similarly, touch that position too. Fig. 15: Touchscreen displaying information After calibrating the touchscreen you can test the alignment by pressing the “Test” button to view the tracking accuracy.
Maintenance and Prevention Maintenance and Prevention Kontron Embedded Computers systems only require minimal maintenance and care to keep them operating correctly. ❏ Occasionally wipe the system with a soft dry cloth. ❏ Remove persistent dirt by use of a soft, slightly damp cloth (use only a mild detergent). Use no abrasives, abrasion sponges, steel wool, metal threads, or solvent like alcohol, acetone, washing gasoline to clean the displays protection pane or the surface of the touchscreen.
Technical Data Technical Data TFT LCD Display Diagonally (Size) active area 19” (376.0 x 301.1 mm) Resolution 1280 x 1024 Pixel Pitch 0.294 mm x 0.
Technical Data Mechanical Specifications Dimensions Panelmount 19" Front plate Front Plate: HxWxD 431 x 482.6 x 5 (mm) 16.97" x 19" x 0.197" HxWxD 399.2 x 482.6 x 5 mm 9U x 19" x 0.197" steel zinc-plated Frontal: black powder coated steel zinc-plated Frontal: black powder coated Height 372 mm (14.646") 372 mm (14.646") Width 427.5 mm (16.831") 427.5 mm (16.831") Depth 70 mm (2.756") 70 mm (2.756") Material steel zinc-plated steel zinc-plated approx. 9.8 kg (21.605 lbs.
Technical Data Environmental Specifications Operating Temperature 0 … +50 °C (32 … 122 °F Storage / Transit temperature –20 … +60 °C (–4 … 140 °F ) Relative Humidity (operating) 20 – 85 % (non-condensing) Humidity (storage) 5 – 85 % (non-condensing) Operating Altitude 10,000 ft (3,048 m) Storage / Transit Altitude 40,000 ft (12,191 m) Operating Shock 15 G, 11 ms duration, half sine Storage/Transit Shock 30 G, 11 ms duration, half sine Operating Vibration 10 – 58 Hz, ± 0.
Technical Data CE Directives and Standards CE Directives Low Voltage Directive (Electrical Safety) 73/23/EEC EMC Directive 89/336/EEC Electrical Safety Standards EUROPE EN 60950-1: 2000 EMC Standards Emission: EN 61000-6-4: 2001 EUROPE Immunity: EN 61000-6-2: 2001 USA 36 FCC 47 CFR Part 15, Class A 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Technical Appendix – Interfaces Technical Appendix – Interfaces The following tables show the plug assignments for the external connections of the KFM19_e. Low-active signals are indicated by a minus sign. VGA Connector Pin Signal Name 1 red 2 green 3 blue 4 4 is NC 5–8 GND 9 Fused VCC 10 GND 11 NC 12 DDC Data 13 HSYNC 14 VSYNC 15 DDC Clock 15-pin D-SUB Socket (female) 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Technical Appendix – Interfaces DVI-D Connector Pin Signal Name Description 1 TMDS2– Differential TMDS Data 2– 2 TMDS2– Differential TMDS Data 2+ 3 GND TMDS Shield 4–5 NC Reserved for future use 6 DVI_SCL DDC EDID data clock 7 DVI_SDA DDC EDID data 8 DVI_VS Analog VSYNC 9 TMDS1– Differential TMDS Data 1– 10 TMDS1+ Differential TMDS Data 1+ 11 GND TMDS Shield 12–13 NC Reserved for future use 14 DVI_5V 5V / 100mA Power Supply 15 GND Ground 16 DISPDET Hot Plug Detec
Technical Appendix – Interfaces S-Video Connector Pin Signal Name Description 1 GND Ground 2 GND Ground 3 Y Luminance 4 C Chrominance 4-pin Mini-DIN Connector (female) C-Video (Composite) Connector Pin Signal Name Description 1 GND Ground 2 CVBS Composite video signal Cinch Connector (yellow) (female) USB Touchscreen Connector Pin Signal Name 1 VCC 2 Data– 3 Data+ 4 GND 4 pin USB Socket Type A Version 1.1 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Technical Appendix – Interfaces Serial Touchscreen Connector (RS232) Pin Signal Name 1 DCD (Data Carrier Detect) 2 RXD (Receive Data) 3 TXD (Transmit Data) 4 DTR (Data Terminal Ready) 5 GND (Signal Ground 6 DSR (Data Set Ready) 7 RTS (Request to Send) 8 CTS (Clear to Send) 9 RI (Ring Indicator) 40 9-pin D-SUB Socket 19" Industrial LCD Monitor KFM19_e – User’s Manual (Version 1.
Technical Support Technical Support For technical support, please contact our Technical Support department. Tel: +49 (0)9461 950-104 Fax: +49 (0)9461 950-200 e-mail: support@kontron.com Make sure you have the following information on hand when you call: • the unit part id number (P/No #), • and the serial number (S/No #) of the unit (provide the serial number found on the type label, placed on the rear side of the system). Be ready to explain the nature of your problem to the service technician.
Technical Support Returning Defective Merchandise Before returning any merchandise, please: 1. Contact our Customer Service department to obtain an RMA (Return Material Authorization) number. Fax: (+49) 8165-77 412 e-mail: service@kontron.com 2. Make sure that you receive an RMA number from Kontron Embedded Computers-Service before returning any merchandise. Clearly write or mark this number on the outside of the package you are returning. 3. Describe the device failure behavior. 4.