4.3.3 Compass
DMT has selected the Honeywell HMR3000 as the preferred compass device. The Honeywell
compass uses a 9-pin serial connector for communications with the AIMS radar. Power is also
provided via this connector (see drawing). The serial communications lines should be attached
to the serial I/O port on the CPU stack via the Molex connector block (pins 7,8 and 9).
Name
In/Out
Pin
Description
TxD
Out
2
RxD
In
3
RS232 Receive / RS485 TxRx
-
GND
In
5
Power and signal common
5V
In
8
Regula
ted power input
6
-
15V
In
9
Unregulated power input
Caution: Do NOT exceed +5.5V at regulated power input (pin 8). Higher voltages
will damage components.
The HMR3000 should already be wired and attached to the stand-post behind the antenna, ready
for configuration.
After installation is completed, you will need restart the AIMS Radar server software and check
the box “Compass” on your Operation tab to begin using your Compass. The communication
parameters should be set on the Compass Tab to the following values;
Port. COM5
Baud Rate. 19200
Data Bits. 8
Parity. None
Stop Bits. 1