Figure 5.154 Input command M415
Calibration
Base Calibration
The base Encoder has been calibrated before being shipped out. Generally, the J1-coordinate
is 0° after homing, where the homing point is the system default. Namely, the Forearm is located at
the middle in front of the base.
If the J1-coordinate is not 0° (error range: 1°-3°) after homing, you need to re-calibrate the
base Encoder.
Prerequisites
The writing and drawing kit has been installed. For details, please see 5.4.1 Installing
a Writing and drawing kit.
Dobot Magician has been powered on.
Dobot Magician has been connected to DobotStudio successfully.
The sensor calibration board has been prepared.
Procedure