" Retrig.
Socket " is the ADSR’s retrigger input, which can be
connected, for instance, to the output from an LFO.
That means that while the gate is open, the envelope
re-triggers every time it senses a pulse from the LFO
(see Fig. 2).
Fig. 2
: Envelope re-trigger system
§ Output • $ Output
Whenever the ADSR is triggered, these
outputs
carry
the envelope voltage as defined by the Attack, Decay,
Sustain and Release parameters (see Fig. 3).
% Inverse Output
The Inverse Output carries exactly the same voltage
envelope as the ordinary outputs but inverted - with
negative instead of positive voltages (see Fig. 3).
Fig. 3
: normal and inverted envelopes
AD
S
R
Output
Inverse
Output
A
DS
R
0 V
- 8 V
0 V
8 V
ADSR
Gate
Retrig.