Installation manual

Dolby
®
Model CP650 Installation Manual B-Chain Alignment
4-4
a
ra
e
Enter Room Reading:
> xx.x dB
Press OK to continue
C
rossover
M
o
d
e
Full Range
Crossover Disabled
4.4 SPL (Sound Pressure Level) Calibration
If your CP650 is equipped with a Cat. No. 791 Crossover Board, an initial setup is
required before you begin the SPL calibration. If you do not have a Cat. No. 791
installed, skip to Section 4.4.2.
4.4.1 Initial Setup (CP650s with Cat. No. 791 Crossover)
SPL calibration of CP650s equipped with a Cat. No. 791 Crossover Board is
performed with the crossover set to “Full Range” mode. Pink noise is applied only to
the CP650 low-frequency (LF) main outputs and these outputs are switched to full-
frequency operation for calibrating the CP650 to the room sound pressure level.
menu
OK
Press the left menu button four times to display
the Crossover Mode screen.
One of three crossover configuration choices is
displayed on the second line: Full Range, 2-Way,
or 3-Way.
Rotate the front-panel knob until Full Range is
displayed.
menu
OK
Press OK to save this setting.
4.4.2 Calibration Procedure (All CP650s)
menu
OK
Press the left menu button twice to move the
display to the Calibrate SPL menu item.
Pink noise is sent to the center channel speaker.
Note: If pink noise is not being generated, this indicates that the
status of the digital input has changed. If you are using the digital
input on the CP650, either disconnect or power down the device
attached the digital input during calibration. A change in the
digital input bitstream will cause the CP650 to mute the pink
noise.