Installation manual
Dolby
®
Model CP650 Installation Manual A-Chain Alignment
5-7
L
L
L
L
RR
RR
✓
✓
OSCILLOSCOPE TRACES
The adjustment is correct when there is no
signal output while the film is running.
It may
not be possible to adjust for a null with some
older slits; in such instances, adjust for a
minimum and equal signal on L and R.
Some projectors use a lens with an adjustable
slit width.
The adjustment is correct at the
point when the left and right signals both
disappear equally.
5.6 Cell Alignment Check
Remove the SMPTE Buzz Track test film and
thread and play the Cat. No. 97 Stereo Cell
Alignment Film.
If a large amount of crosstalk is present on the
scope display, loosen the stereo solar cell head
and move it from side to side until the crosstalk
is minimum and equal.
Note: The Right channel is the track toward the outside of
the projector. On some projectors, it may be necessary to
stop the film to adjust the position of the cell.
Lock the cell bracket into position after
completing this adjustment. Check that the
crosstalk does not change as the bracket is
tightened.