Specifications
MC55 AT Command Set
17.12 AT^SNFM
s
MC55_ATC_V03.03 Page 399 of 459 9/9/05
Confidential / Released
Microphone supply voltage control status.
0 Supply voltage was set to a constant value.
2 Supply voltage state is controlled by the ME and depends on parameter data
set of the selected audio mode.
Notes
• The programmable power supply of the MICP2 line gives you greater flexibility in connecting audio accesso-
ries or using MICP2 for a variety of functions other than audio. A detailed description of the extended usage
of MICP2 can be found in [8].
• During an active call, users should be aware that when they switch back and forth between different audio
modes (for example handsfree on/off) the value of <MicSwitch> does not change, i.e. the microphone mode
is retained until explicitly changed.
<MicVccState>
(num)