Operating instructions
- 11 -
STARTING THE REFRIGERATOR
1.  Check that all the manual gas valves are in the 
ON position.
2.  Make sure that a continuous 12 VDC supply is  
available for the electronic control to function.
3.  Press the ON/OFF button. 
4.  Select operation mode:
 - AUTO mode (AC and LP gas) 
Press the AUTO/GAS mode selector button 
(if not already on).
 - GAS mode (LP gas operation only) 
Press the AUTO/GAS mode selector button 
to turn off the AUTO mode (if not already off).
ADJUSTING THE THERMOSTAT
The adjustable thermostat ranges from 1 - 5 (5 = coldest  
temperature setting). 
After the initial start-up, adjust the thermostat by 
pressing the TEMP. SET button repeatedly until 
the desired setting is displayed. 
The thermostat controls both the gas and electric opera-
tion. Thus, it is not necessary to reset each time a differ-
ent energy source is employed.
INSTRUCTIONS FOR USE
OPERATING THE ICE MAKER
RM1350IM, RM1350MIM, RM1350WIM & RM1350WID 
Before the ice maker can operate, make sure that:
• The refrigerator is connected to 120 VAC . 
• The water valve supplying the refrigerator is turned on.
• The ice level bail arm is in its fully down position.
When the ice maker thermostat senses the preset tempera-
ture for the ejection of the ice cubes, the ngers will start to 
rotate, dumping any ice cubes and lling the mold with water.  
When the storage container is full, the bail arm will come 
in contact with the ice cubes. The bail arm cannot return 
to the full down position and the ice production is stopped 
until the bin is emptied, or ice cubes are removed. 
To prevent water from splashing out of the mold assembly 
while travelling in your recreational vehicle, raise the bail 
arm to the full UP/OFF position about 1-1/2 hours before 
departing. This will allow the water in the mold to freeze. 
WATER SUPPLY
The  water  supply  system  must  have  a  minimum  pres-
sure of 15 pounds  per square inch gauge (psig). A 1/4" 
diameter water line to the water valve should be used at 
the  rear  of  the  refrigerator.  The  water  line  must  have  a 
manual shutoff valve placed where it is easily accessible.
The maximum water level is represented by a thin line. It 
is essential that the water level does not exceed this line! 
If necessary,change the water ow by adjusting the water  
supply.  For  instructions,  see ADJUSTING  THE  SIZE  OF 
CUBES.
LP GAS EQUIPMENT ASSEMBLY
BURNER TUBE .
 SPARK ELECTRODE
 BURNER JET
BURNER MOUNTING
SCREWS
 PRESSURE TEST PORT
 MANUAL SHUTOFF VALVE
 Shown in open position
 INLET FITTING
SOLENOID VALVE
Maximum 
water level
Ice level
bail arm
Down
position
FIRE  HAZARD.  When  the  RV  has  not  been 
used for some time, make sure that the path 
between the burner jet and the burner tube 
has not been obstructed before lighting the 
LP gas burner. Failure to obey this warning 
could cause a re resulting in death or seri-
ous injury.