TROUBLESHOOTING
SYMPTOM CHECK/REMEDIAL ACTION
Refrigerator stops cooling • Immediately turn the refrigerator off and contact a Dometic dealer or Service Center.  
NOTE! Do not leave it running for an extended period of time, and never try to solve the 
problem by repeatedly restarting the refrigerator.
• Do not use the refrigerator until it has been repaired.
Refrigerator emits an am-
monia smell 
• Immediately turn the refrigerator off at front control panel.
• Do NOT open refrigerator doors. 
• Open coach windows and door (to air out the coach) and evacuate.
• Turn off manual LP gas valve at rear of refrigerator.
• Disconnect the 120 VAC power at rear of refrigerator.
• Contact a Dometic dealer or Service Center for repair.
• Do not use the refrigerator until it has been repaired.
Refrigerator or freezer is 
not cold enough 
• Check the thermostat and adjust if necessary. 
• Is there a power failure?
• Is the refrigerator level? (Due to the nature of its operation it is important to keep an  
absorption refrigerator level.)
• Door closing properly? Check the door gasket.
• Heavy frost build-up on evaporator ns? To prevent frost buildup do not leave the unit’s 
door open longer than necessary. 
• Over packed refrigerator? The unit will have to work harder if the refrigerator is stuffed, 
and results in higher cabinet temperatures. Arrange the food in the unit to allow for free 
air circulation. 
Refrigerator does not work 
on electric
• Is the plug rmly connected to the receptacle? Is the receptacle energized? Check the 
receptacle by plugging in another appliance. 
• Is there a power failure?
• Blown fuse. Turn refrigerator off and contact a Dometic dealer or Service Center for repair.
Refrigerator does not work 
in gas operation mode
• LP gas bottle empty? Change the gas bottle.
• Air in the gas pipe? Remove air by repeating the ignition sequence.
• If the problem persists, turn refrigerator off and contact a Dometic dealer or Service Center 
for repair.
Refrigerator emits an odor 
from fumes
• Dislocated or damaged burner. Turn refrigerator off and contact a Dometic dealer or Service 
Center for repair.
• Dirty ue tube. Turn refrigerator off and contact a Dometic dealer or Service Center for repair.
“LP” is ashing
(The message alternates 
between “LP” and the 
fresh food compartment 
temperature.)
• LP gas ignition failed. The refrigerator went through a complete ignition sequence, and the 
burner did not light. Turn refrigerator OFF and then back ON to return to normal operation.
• Air in the gas line? After changing a gas bottle or after a long shutoff period, the gas line is 
likely to be lled with air. You may have to repeat the lighting procedure (45 seconds) by 
turning the refrigerator off and on several times in order to purge the air out of the gas lines.
• LP gas bottle empty and needs replacing.
•  Obstruction in or on the burner or burner jet, or burner jet is clogged and should be cleaned.  
Turn refrigerator off and contact a Dometic dealer or Service Center for repair.
If the problem persists and the refrigerator is still not working properly, turn refrigerator off and contact your nearest Service 
Center. State the problem, model, product, and serial number. These details are stated on the data label inside the fresh 
food compartment.
TROUBLESHOOTING TABLE
If you run into a problem, refer to the troubleshooting table below. If an error code is displayed, please see “Error Codes” 
for more information.