PerfectPower Fastening and connecting the inverter
15
Connecting the inverter to the 230 V mains supply
Plug the 230 V connection cable into the connector for the 230 V power supply
to the inverter (fig. 1 2, page 3).
Connect the 230 V connection cable to a 230 V socket in the vehicle.
Connecting the remote control to the inverter
Switch off the inverter.
Insert the cable end of the remote control into the connection (fig. 2 2,
page 3).
Set the main switch (fig. 2 1, page 3) to “Remote”.
Connecting the external switch contact to the inverter
Switch off the inverter.
Connect the external switch contact (power supply from the inverter) at the
remote port (fig. 2 3, page 3) in accordance with the wiring diagram (fig. 3,
page 3),
Set the main switch (fig. 2 1, page 3) to “Remote”.
I
8.3 Connecting multiple consumers
!
The device is equipped at delivery with galvanic isolation. For the safe operation of
multiple consumers, it is essential that a circuit breaker (residual current circuit
breaker) is built into the socket distribution circuit, see sample circuit diagram in
fig. 6, page 5.
NOTE
If you wish to use an external switch contact with a power supply of it
own, e.g. the ignition, you must interconnect a suitable relay.
WARNING! Danger of electrocution!
If you wish to connect more than one consumer to the inverter and install
a socket distribution circuit, you must arrange a circuit breaker (residual
current circuit breaker) and set a grounding bridge in the inverter. The
grounding bridge may only be connected by a trained professional who
is familiar with the relevant VDE (German Engineering Society) regula-
tions.