User Manual

Page 10
5. Testing the Inverter:
Enerdrive Inverter is ON. AC output is now available.
Plug in a small AC load like a 25W table lamp or small appliance to the AC socket to verify AC is
available.
The unit is successfully installed and functioning properly.
6. Unit Operation
WARNING: RISK OF EQUIPMENT DAMAGE
Do not connect an AC power source like utility power or generator to the unit AC outlets.
Turn ON and OFF the unit:
will turn ON to indicate the unit is powered up.
AC Output is available at the AC output socket and 5V USB port.
the unit is powered down on the AC output.
Understanding the ‘Power Save’ function
The unit can be pre-set with the ‘Power Save’ function ON or OFF. If the unit is turned ON with ‘Power
Save’ function pre-set to ON, with any AC load greater than>10W connected to the unit, the unit will
provide continuous AC Output.
With any AC load less than <10W connected to the unit or with AC Load changing from >10W to <
5W, the AC Output will change from continuous to pulsing the AC Output every 5 seconds.
The unit is default set toPower Save’ OFF. To change thePower Save’ function from OFF to ON or
Turn unit on by using the On/Off button on the unit. The ‘Power’ light turns on indicating the
Press the Green On/Off button OFF the inverter. The status indicator will turn OFF to indicate
Press and hold the Green On/Off button for 1-2 seconds to turn ON the inverter. The status indicator
switch back from ON to OFF, press and hold the green ‘On/Off’ button for more than 5 seconds until
the ‘Status’ light quickly flashes three times and the alarm beeps for more than 2 seconds.
Enerdrive Inverter 600W 12V Owners Manual Rev: 1.7