Special Features
Auto Fan
When auto fan is selected the fan speed will vary depending on the
difference between the temperature set-point and the room tempera-
ture. In auto fan the compressor and fan cycle On and Off with the
thermostat.
When the difference is:
>5º The fan operates on HIGH
<4º The fan operates on LOW
Compressor Time Delay
A time delay of approximately two minutes occurs any time the com-
pressor is required to begin the cooling or heat pump cycle.
Defrost Cycle
During heat pump operation, if the outside coil begins to freeze
up, a defrost cycle is initiated that temporarily puts the heat pump
back into air conditioning mode. This reverses the refrigerant ow
and melts the ice forming on the outside coil. Typically this oc-
curs when the outside temperatures are below 42 °F and repeats
every 25 minutes of compressor run time as long as the outside
temperature stays below 42 °F and above 30 °F. Therefore, dur-
ing this period of operation you, (the user) will temporarily feel
cold air inside the RV at the registers. This is normal and is NOT
an indication of malfunction. (Note: Defrost cycling shall con-
tinue until the measured temperature of the Outdoor Sensor is
≤30°For≥42°F.)