Upper vent insert...............AS1625i Alum
flue tube....................Alumtube Lower
vent set consists of:
Lower frame.......................RS1650L
Lower vent..........................AS1635L
Mounting frame cut out size: Width 451 height 156
Open area of upper vent: 328 cm
2
Open area of lower vent: 350 cm
2
Gas flue extension each extension add 43mm to the height of the Tee piece. Part
LS300 vent and frame cut out required 490mm x 249mm open
ventilation area 667 cm
2
Gas flue kit: Part number... 3776
Motor home vent roof cap: Part number ...3311246.000 width:
310mm length: 670mm height:100mm
Combined with
Motor home vent roof base: Part
number...3311237.000 width: 210mm length:660 height:
95mm Assembled over all dimensions...
width: 310mm length: 670 height: 125mm Open ventilation area: 730 cm
2
Motor home wall vent: Part number...3109350.110
Over all: width 587mm height:385mm
Cut out required: width: 550 height: 350mm
Clear opening with vent removed: width:556mm Height: 303mm
Open ventilation area: 4450cm
2
Note: These ventilation options are intended to compliment the original installation and operating instructions
supplied with each Dometic refrigerator and are the preferred ventilations systems for all Dometic absorption
refrigerators.
Current AS/NZS 5601.2:2010 and future amendments to the gas installation regulations must be
adhered to at all times.
Warranty claims due to incorrectly ventilated, installed or flued refrigerators are not covered by the usual Dometic two year
Australian wide warranty. All details are subject to alteration without notice.
V5