Specifications

10
Symptom Possible Cause Service Instruction
10. Flush ball will not close
completely.
Component adjustment required or
defective component.
Rotor shaft cam is loose or
defective. If defective, see
replacement instructions, p. 12.
11. Squeaky noise occurs when
ush ball is opening.
Lubrication of component(s) is
required.
Drive arm/drive linkage joint
needs lubricated with silicone
grease.
Flush ball and seal needs
lubricated with silicone spray.
12. Water will not stay in bowl
(leaks down through ush ball
seal).
Incomplete seal between
ush ball and rubber seal.
Cam switch needs adjustment
(see adjustment procedure for
ush ball over-travel, p. 11).
Mounting bolts that hold base
assembly to ceramic toilet need
tightened. Caution: Excessive
tightening of bolts can damage
toilet.
Flush ball seal is worn and
needs replaced. See instruc-
tions, p. 11.
Flush ball is worn and needs
replaced. See instructions,
p. 12.
13. Toilet ushes in both “Add
Water” and “Flush” switch
positions.
Defective electrical
component.
Diode D2 on terminal block pins
1 and 2 is defective. Replace
with new diode.
14. Water will not enter toilet bowl
during “Flush” cycle.
Defective electrical
component.
Diode D2 on terminal block pins
1 and 2 is defective. Replace
with new diode.
15. Water is leaking from toilet
onto oor.
Loose connection or defective
component.
Loose water line connection.
Tighten connection.
Loose or defective vacuum
breaker. Replace if defective.
Defective water valve. Replace
with new water valve.
Ball seal is defective and needs
replaced. See instructions, p. 11.
Mounting bolts that hold base
assembly to ceramic toilet need
tightened to 20-25 in.-lbs. of
torque. Caution: Excessive
tightening of bolts can damage
toilet.
Maintenance/winterizing/service Dometic 4300/4400 Series Toilets
Caution - Motor starts automatically
Turn off electrical power before servicing.
Caution - Electrical system
Turn off electrical power before servicing.