Specifications

10
ANALOG DUCTED INSTALLATION INSTRUCTIONS
8. INSTALLATION OF COLD CONTROL
A. Remove parts package, control box and thermostat from the 3107541.XXX or 3107546.XXX Control Kit carton.
B. Freeze Control Installation 579, 590, 591, & 595 Series Brisk Air Models (See FIG. 7.)
1. Snap freeze control into place on return bend located at left side of evaporator coil as follows:
a. Locate ā€œDā€ shaped notch in flange of evaporator coil.
b. Place the horseshoe end of the freeze control through this notch and snap onto the coil return bend. When positioned
correctly, control wires will be 90
0
to direction of coil fin surface.
c. Remove installation notice hang tag from freeze control.
C. Freeze Control installation on 600 Series Penguin Models (See FIG. 8.)
1. Snap freeze control into place on return bend located at right side of evaporator coil as follows:
a. Locate ā€œDā€ shaped notch in flange of evaporator coil.
b. Place the horseshoe end of the freeze control through this notch and snap onto the coil return bend. When positioned
correctly, control wires will be 90
0
to direction of coil fin surface.
c. Remove installation notice hang tag from freeze control.
FIG. 8
FIG. 7
Brisk Air Model Series
579, 590, 591, & 595
Coil
Return
Bend
Remove
Hang Tag
Freeze Control
With Wires To Left Side
Penguin Model Series 600
Coil
Return
Bend
Remove
Hang Tag
Freeze Control
With Wires To Right Side