Specifications
16
ANALOG DUCTED INSTALLATION INSTRUCTIONS
POWER
+
K5
WHITE
BLACK
RELAY BOARD
USE COPPER CONDUCTORS
USE COPPER CONDUCTORS
GRN/YEL
115 VAC 60 Hz 1 O
115 VAC 60 Hz 1 O
PART No. 3107546.008
PART No. 3107546.008
59146
FOR A/C WITH HEATPUMP
FOR A/C WITH HEATPUMP
FOR USE WITH AIR CONDITIONER:
FOR USE WITH AIR CONDITIONER:
YELLOW
LINE SPLICE
LINE SPLICE
FACTORY WIRING
FIELD WIRING
FIELD WIRING
GRY/YEL
LO FAN
LO FAN
FROM A/C
CONNECTION
ELECTRICAL
WHITE
RED
K4
COM
N.O.
COM
N.O.
HI FAN
HI FAN
BLACK
BLUE
BLACK
RED
SUPPLY
T-STAT
YELLOW
WHITE
VIOLET
ORANGE
BLUE
SERIAL No.
3107543.021
LAGRANGE, IN 46761
LAGRANGE, IN 46761
509 S. POPLAR ST.
509 S. POPLAR ST.
BLUE/WHITE
BLUE/WHITE
T4
12 VDC
12 VDC
RED
BLACK
-
E155095
115VAC, 60Hz, 1PH
115VAC, 60Hz, 1PH
1
2
3
4
5
6
3 AMP FUSE
FURNACE
T3
ONLY
SOLAR/FILTER
INDICATOR
IF USED
IF USED
PASSED
DIELECTRIC
R
POWER
+
FREEZE
FREEZE
K5
WHITE
BLACK
RELAY BOARD
USE COPPER CONDUCTORS ONLY
USE COPPER CONDUCTORS ONLY
GRN/YEL
115VAC60Hz1O
115 VAC 60 Hz 1 O
CONTROL (N.O.)
CONTROL (N.O.)
PART No. 3107541.017
PART No. 3107541.017
579, 590, 595, 600
579, 590, 595, 600
FOR A/C WITH OPTIONAL HEATSTRIP
FOR A/C WITH OPTIONAL HEATSTRIP
FOR USE WITH AIR CONDITIONER:
FOR USE WITH AIR CONDITIONER:
N/C
LINE SPLICE
LINE SPLICE
FACTORY WIRING
FIELD WIRING
FIELD WIRING
GRY/YEL
LO FAN
LO FAN
FROM A/C
CONNECTION
ELECTRICAL
ELECTRICAL
WHITE
WHITE
RED
K4
COM
N.O.
COM
N.O.
HI FAN
HI FAN
BLACK
BLUE
GREEN
RED/WHT
SUPPLY
T-STAT
YELLOW
WHITE
ORANGE
TAN
BLUE
SERIAL No.
T3
3107759.015
3107759.015
LAGRANGE, IN 46761
LAGRANGE, IN 46761
509 S. POPLAR ST.
509 S. POPLAR ST.
BLUE/WHITE
BLUE/WHITE
BLUE/WHITE
BLUE/WHITE
T4
HS
FURNACE
12 VDC
12 VDC
RED
BLACK
-
E155095
E155095
115VAC, 60Hz, 1PH
115VAC, 60Hz, 1PH
GRAY
N/C
WHITE
1
2
3
1
2
3
4
5
6
3 AMP FUSE
INDICATOR
SOLAR/FILTER
PASSED
DIELECTRIC
IF USED
IF USED
R
BLUE/WHITE
RED
TAN
BLUE/WHITE
BLACK
BLUE
YELLOW
WHITE
RED/WHT
GREEN
BLUE
BLACK
N/C
RED
WHITE
GRY/YEL
3 AMP FUSE
1
2
3
4
5
6
ELECTRIC
CONNECTION
FROM A/C
T-STAT
FURNACE
12 VDC
12 VDC
POWER
SUPPLY
-
+
E155095
PART No. 3107541.009
PART No. 3107541.009
SERIAL No.
FOR USE WITH AIR CONDITIONER:
FOR USE WITH AIR CONDITIONER:
579, 590, 595, 600
579, 590, 595, 600
WITHOUT HEATSTRIP OPTION
509 S. POPLAR ST.
509 S. POPLAR ST.
LAGRANGE, IN 46761
LAGRANGE, IN 46761
115VAC, 60Hz, 1PH
115VAC, 60Hz, 1PH
T3
T4
RELAY BOARD
K4
N.O.
COM
LO FAN
LO FAN
HI FAN
HI FAN
BLACK
WHITE
GRN/YEL
FIELD WIRING
FIELD WIRING
FACTORY WIRING
LINE SPLICE
LINE SPLICE
115 VAC 60 Hz 1 O
115 VAC 60 Hz 1 O
USE COPPER CONDUCTORS
USE COPPER CONDUCTORS
3107750.014
FREEZE
CONTROL (N.O.)
R
SOLAR/FILTER
INDICATOR
ONLY
PASSED
DIELECTRIC
IF USED
IF USED
12. RELAY KIT FIELD WIRING DIAGRAM
COOLING/FURNACE
COOLING/FURNACE/HEAT STRIP
COOLING/FURNACE/ HEAT PUMP