Operating instructions

3
579, 590 & 595 Air Distribution Box With Analog Relay Kit Installation Instructions
MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC INSTALLED MINIMUM
NO. CAPACITY RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STATIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR
(BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN *** USER (POUNDS) SIZE**
COOLING AMPS AMPS “ W. C. SUPPLIED 1 UNIT/ 2 UNITS
57908.521 7,100 6.6 34.0 2.5 5.8 325 / 250 0.55 / 0.90 17.0 20 Amp 75 2.5 KW / 4.0 KW
57912.622 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 94 2.5 KW / 4.0 KW
57912.631 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 94 2.5 KW / 4.0 KW
57915.322 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 100 3.5 KW / 5.0 KW
57915.331 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 100 3.5 KW / 5.0 KW
57915.422 13,500 11.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 14.5 20 Amp 100 3.5 KW / 5.0 KW
57915.522 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.531 13,500 12.7 60.0 2.0 5.6 325 / 250 0.55 / 0.90 16.5 20 Amp 102 3.5 KW / 5.0 KW
57915.536 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.541 13,500 11.3 62.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.546 13,500 11.3 62.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW
57915.622 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.631 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW
57915.731 13,500 11.3 56.0 2.5 5.8 325 / 250 0.55 / 0.90 15.0 20 Amp 94 3.5 KW / 5.0 KW
59016.521 15,000 12.9 71.0 2.5 6.0 350 / 250 0.40 /1.1 0 26.5 20 Amp 101 3.5 KW / 5.0 KW
59016.621 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 26.5 20 Amp 101 3.5 KW / 5.0 KW
59516.303 15,000 12.7 60.0 2.0 5.6 350 / 250 0.40 / 1.10 29.0 20 Amp 102 3.5 KW / 5.0 KW
59516.331 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 29.0 20 Amp 94 3.5 KW / 5.0 KW
59516.336 15,000 12.7 60.0 2.0 5.6 325 / 250 0.40 / 1.10 29.0 20 Amp 94 3.5 KW / 5.0 KW
59516.501 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 31.0 20 Amp 94 3.5 KW / 5.0 KW
59516.531 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 26.5 20 Amp 94 3.5 KW / 5.0 KW
59516.536 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 29 20 Amp 94 3.5 KW / 5.0 KW
59516.601 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 31.0 20 Amp 102 3.5 KW / 5.0 KW
59516.603 15,000 12.3 77.0 2.0 5.6 325 / 250 0.40 / 1.10 29.5 20 Amp 102 3.5 KW / 5.0 KW
59516.631 15,000 12.9 71.0 2.0 6.0 325 / 250 0.40 / 1.10 31.0 20 Amp 102 3.5 KW / 5.0 KW
SPECIFICATIONS
120VAC,
60 HZ., 1PH.
12 AWG
Copper
up to 24’
* For wire lengths over 24 ft. consult the National Electric Code for proper sizing.
** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications
When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and
from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.