Operating instructions

107
NOTE: If a remote sensor is used, it must be
plugged into the P4 (white) connector.
Improper connections can cause
component damage.
2. ONE ROOFTOP AIR CONDITIONER PLUS ONE
GAS FURNACE
To configure one rooftop air conditioner plus one
gas furnace, all Dip switches are "OFF" and the
freeze control is plugged into the proper connector
(blue) 115VAC, 12VDC. Two thermostat wires
from the furnace and telephone cable communica-
tions line are properly connected to the air condi-
tioner electronic control box.
FURNACE
FURNACE
2 WIRES
CIRCUIT
BREAKER BOX
12V DC INPUT
2 WIRES
115V AC
DUO-THERM
COMFORT CONTROL
TELEPHONE CABLE
COMMUNICATIONS LINE
Typical installation for one com-
fort zone with rooftop air and
furnace. Comfort control may
serve as a room temperature
sensor, or a remote sensor may
be used.