Operating instructions

109
4. ONE ROOFTOP HEAT PUMP PLUS ONE GAS
FURNACE
To configure one rooftop heat pump plus one gas
furnace, all Dip switches are OFF. The freeze control
is NOT used. The blue connector must stay open (P5).
The ambient sensor is plugged into the proper connec-
tor (red). 115VAC, 12VDC, two thermostat wires from
the furnace and telephone cable communications line
are properly connected to the heat pump electronic
control box.
FURNACE
FURNACE
2 WIRES
CIRCUIT
BREAKER BOX
12V DC INPUT
2 WIRES
115V AC
DUO-THERM
COMFORT CONTROL
TELEPHONE CABLE
COMMUNICATIONS LINE
Typical installation for one com-
fort zone with rooftop heat pump
and one furnace. Comfort control
may serve as a room temperature
sensor, or a remote sensor may
be used.
NOTE: If a remote sensor is used, it must be plugged
into the P4 (white) connector.
Improper connections can cause
component damage.