5. ONE BASEMENT AIR CONDITIONER PLUS ONE
GAS FURNACE
To configure one basement air conditioner plus one
gas furnace, all Dip switches are OFF. 115VAC,
12VDC, two thermostat wires from the furnace and
telephone cable communications line are properly
connected to the air conditioner electronic control box.
NOTE: If a remote sensor is used, it must be plugged
into the P4 (white) connector.
Improper connections can cause
component damage.
Typical installation for one com-
fort zone with basement air and
one furnace. Comfort control may
serve as a room temperature
sensor, or a remote sensor may
be used.
CIRCUIT
BREAKER
BOX
115V AC
TELEPHONE CABLE
COMMUNICATIONS LINE
FURNACE
FURNACE
2 WIRES
ALL WIRING REMOTE
ELECTRICAL BOX ATTACHMENT
BASEMENT AIR
12V DC INPUT
2 WIRES
DUO-THERM
COMFORT CONTROL