6. ONE BASEMENT HEAT PUMP PLUS ONE GAS
FURNACE
To configure one basement heat pump plus one gas
furnace, all Dip switches are OFF. The ambient
sensor is plugged into the proper connector (red).
115VAC, 12VDC, two thermostat wires from the
furnace and telephone cable communications line are
properly connected to the AC power module in the
unit's electrical box.
NOTE: If a remote sensor is used, it must be plugged
into the P4 (white) connector.
Improper connections can cause
component damage.
Typical installation for one com-
fort zone with basement heat
pump and one furnace. Comfort
control may serve as a room
temperature sensor, or a remote
sensor may be used.
CIRCUIT
BREAKER
BOX
115V AC
TELEPHONE CABLE
COMMUNICATIONS LINE
FURNACE
FURNACE
2 WIRES
ALL WIRING REMOTE
ELECTRICAL BOX ATTACHMENT
BASEMENT HEAT PUMP
12V DC INPUT
2 WIRES
DUO-THERM
COMFORT CONTROL