Operating instructions
120
ZONE 1 configuration should have all Dip switches to
OFF position. (Refer to Figure "ZONE 1")
ZONE 2 configuration should have Dip switch 5 (ZONE
2) to ON position and all other Dip switches to OFF
position. (Refer to Figure "ZONE 2")
NOTE: If a remote sensor(s) is used, it must be
connected into the P4 (white) connector.
Improper connections can cause
component damage.
5. TWO BASEMENT AIR CONDITIONERS PLUS ONE
GAS FURNACE
To configure two basement air conditioners plus one
gas furnace, ZONES need to be established. For
explanation purposes, the front unit will be ZONE 1,
and the rear unit will be ZONE 2. Zones can be
arranged per the customer's wishes.
EACH unit must have 115V AC Only one unit requires
12VDC. Telephone communications line must be be-
tween the Comfort Control Center and ONE unit.
Another telephone communications line must be be-
tween the two units.
Two (2) furnace thermostat wires must be routed to
ONE unit.
For explanation purposes the 12VDC, Comfort Con-
trol Center telephone communications line and the two
(2) furnace thermostat wires are to ZONE 1 (front) unit.
(Refer to Diagram on top of Next Page)
ZONE 1
ZONE 2