Operating instructions

60
4E. MECHANICAL CONTROLS
This type of heat pump has an air distribution box that has
a mechanical selector switch and thermostat installed in it.
NOTE: Remember to check the installation and operating
instructions for the specific model you are diagnosing.
CONTROLS:CONTROLS:
CONTROLS:CONTROLS:
CONTROLS:
The
Selector SwitcSelector Switc
Selector SwitcSelector Switc
Selector Switc
hh
hh
h has eight positions including
"OFF". This controls fan speed, heating mode and cool-
ing modes.
The
ThermostatThermostat
ThermostatThermostat
Thermostat controls the temperature range
from 65°F. on the coldest side to 90°F. on the warmest
side. In the cooling/heating mode, the compressor ON/
OFF is controlled by the thermostat setting.
COOLING OPERATION:COOLING OPERATION:
COOLING OPERATION:COOLING OPERATION:
COOLING OPERATION:
Set the thermostat at the desired temperature level.
Select the fan speed that best satisfies your needs:
a.
HIGH COOLHIGH COOL
HIGH COOLHIGH COOL
HIGH COOL: Selected when maximum cooling and
dehumidification required.
b.
LOW COOLLOW COOL
LOW COOLLOW COOL
LOW COOL: Selected when room is at desired
comfort level and needs to be maintained. Normally
this speed is used for nighttime operation.
NOTENOTE
NOTENOTE
NOTE: The blower runs continuously to circulate air and
maintain an even temperature. The compressor will come
on when cooling is required to maintain the selected
temperature level.
AFTER SHUTTING THE HEAT PUMP DOWN WITHAFTER SHUTTING THE HEAT PUMP DOWN WITH
AFTER SHUTTING THE HEAT PUMP DOWN WITHAFTER SHUTTING THE HEAT PUMP DOWN WITH
AFTER SHUTTING THE HEAT PUMP DOWN WITH
EITHER SELECTOR SWITCH OR THERMOSTAT, WAITEITHER SELECTOR SWITCH OR THERMOSTAT, WAIT
EITHER SELECTOR SWITCH OR THERMOSTAT, WAITEITHER SELECTOR SWITCH OR THERMOSTAT, WAIT
EITHER SELECTOR SWITCH OR THERMOSTAT, WAIT
AT LEAST TWO (2) MINUTES BEFORE RESTARTING.AT LEAST TWO (2) MINUTES BEFORE RESTARTING.
AT LEAST TWO (2) MINUTES BEFORE RESTARTING.AT LEAST TWO (2) MINUTES BEFORE RESTARTING.
AT LEAST TWO (2) MINUTES BEFORE RESTARTING.
THIS ALLOWS THE REFRIGERANT PRESSURE TOTHIS ALLOWS THE REFRIGERANT PRESSURE TO
THIS ALLOWS THE REFRIGERANT PRESSURE TOTHIS ALLOWS THE REFRIGERANT PRESSURE TO
THIS ALLOWS THE REFRIGERANT PRESSURE TO
EQUALIZE AND COMPRESSOR TO RESTART EAS-EQUALIZE AND COMPRESSOR TO RESTART EAS-
EQUALIZE AND COMPRESSOR TO RESTART EAS-EQUALIZE AND COMPRESSOR TO RESTART EAS-
EQUALIZE AND COMPRESSOR TO RESTART EAS-
ILY.ILY.
ILY.ILY.
ILY.
FAN OPERATION:FAN OPERATION:
FAN OPERATION:FAN OPERATION:
FAN OPERATION:
This will circulate the air in your RV without cooling or
heating. There are two positions: HIGH FAN or LOW FAN
to select from, depending upon personal choice.
HEATING OPERATION:HEATING OPERATION:
HEATING OPERATION:HEATING OPERATION:
HEATING OPERATION:
NOTENOTE
NOTENOTE
NOTE: This heat pump will not replace a furnace for heating
your RV in cold weather. The intent is to remove the chill on
cool days or mornings.
1. Turn the selector switch to "HEAT PUMP";
2. The Fan and Compressor will come on and begin heat-
ing.
3. When desired temperature level in RV is reached, the
blower will run continuously to circulate air and main-
tain an even temperature. The compressor will cycle as
required to maintain selected temperature.
OFF POSITIONOFF POSITION
OFF POSITIONOFF POSITION
OFF POSITION: This position turns the unit off.
5E. ELECTRONIC (DIGITAL)
CONTROLS
This type of heat pump is controlled by a DIGITAL wall-
mounted thermostat. The air distribution can be an air
distribution box or a ducted air system.
NOTENOTE
NOTENOTE
NOTE: Remember to check the installation and operating
instructions for the specific model you are diagnosing.
DIGITAL THERMOSTAT OPERATIONDIGITAL THERMOSTAT OPERATION
DIGITAL THERMOSTAT OPERATIONDIGITAL THERMOSTAT OPERATION
DIGITAL THERMOSTAT OPERATION
Your heat pump is operated from the control panel of the
electronic wall thermostat. When the furnace is connected
to this thermostat, it will operate from the same control
panel.
Identification and operational descriptions for all con-
trol panel switches and display are listed below:
A.
Liquid Crystal DisplayLiquid Crystal Display
Liquid Crystal DisplayLiquid Crystal Display
Liquid Crystal Display: This display will be illumi-
nated any time the system is in operation.
NOTENOTE
NOTENOTE
NOTE:
When switching from OFF to any other mode, the
liquid crystal display may not illuminate for approxi-
mately three minutes.
The display shows the operator both the mode of the
display (indicated by the arrow at the left side of the
display), and the temperature for that mode.
There are three display modes: ACTUAL, COOL
and HEAT.
The operator may choose the mode he desires to
view by depressing the "MODE" switch. Each time
the MODE switch is depressed, the display ad-
vances to the next mode. If the display is left in either
COOL or HEAT, the thermostat will automatically
return the display to ACTUAL in approximately three
minutes.
DIGITALDIGITAL
DIGITALDIGITAL
DIGITAL