7E. DC VOLT REQUIREMENTS
DC VOLTSDC VOLTS
DC VOLTSDC VOLTS
DC VOLTS
On certain models of electronic heat pumps, a DC volt
supply is wired to the control board. The operating range
is 10 to 16 volts. If voltage is below 10 volts, you could
experience improper operation of the components within
the heat pump.
NOTE: See Section 4.2B & C for Thermostat Wiring.
COMPONENTS
MAKE SURE THAT THE POWER SUPPLY TO THEMAKE SURE THAT THE POWER SUPPLY TO THE
MAKE SURE THAT THE POWER SUPPLY TO THEMAKE SURE THAT THE POWER SUPPLY TO THE
MAKE SURE THAT THE POWER SUPPLY TO THE
UNIT IS DISCONNECTED BEFORE PERFORMINGUNIT IS DISCONNECTED BEFORE PERFORMING
UNIT IS DISCONNECTED BEFORE PERFORMINGUNIT IS DISCONNECTED BEFORE PERFORMING
UNIT IS DISCONNECTED BEFORE PERFORMING
ANY WORK ON THE UNIT TO AVOID THE POSSIBIL-ANY WORK ON THE UNIT TO AVOID THE POSSIBIL-
ANY WORK ON THE UNIT TO AVOID THE POSSIBIL-ANY WORK ON THE UNIT TO AVOID THE POSSIBIL-
ANY WORK ON THE UNIT TO AVOID THE POSSIBIL-
ITY OF SHOCK INJURY OR DAMAGE TO THE EQUIP-ITY OF SHOCK INJURY OR DAMAGE TO THE EQUIP-
ITY OF SHOCK INJURY OR DAMAGE TO THE EQUIP-ITY OF SHOCK INJURY OR DAMAGE TO THE EQUIP-
ITY OF SHOCK INJURY OR DAMAGE TO THE EQUIP-
MENT.MENT.
MENT.MENT.
MENT.
8E. SELECTOR SWITCH
The selector switch in a mechanical heat pump has
several positions. The various switch positions can be
tested for continuity with a volt/ohm meter set on the
highest ohm scale.
A.A.
A.A.
A.
MODEL 59126.501MODEL 59126.501
MODEL 59126.501MODEL 59126.501
MODEL 59126.501
First turn the 20 amp heat pump breaker to OFF. Next,
remove the wires from the switch. With the switch in
the OFF position, you should not have continuity be-
tween Terminal L1 and any other white numbered ter-
minal.
In the HIGH 2 FAN position, you should have con-
tinuity between Terminal L1 and Terminal 4 only.
In the HIGH 1 FAN position, you should have con-
tinuity between Terminal L1 and Terminal 2 only.
In the LOW FAN position you should have conti-
nuity between Terminal L1 and Terminal 1 only.
In the LOW COOLING position, you should have
continuity between Terminal L1 and Terminal C; and
Terminal L1 and Terminal 1 only.
In the HIGH 1 COOLING position, you should have
continuity between Terminal L1 and Terminal C; and
Terminal L1 and Terminal 2 only.
In the HIGH 2 COOLING position, you should have
continuity between Terminal L1 and Terminal C; and
Terminal L1 and Terminal 4 only.
In the HEAT PUMP position, you should have con-
tinuity between Terminal L1 and Terminal H; and Ter-
minal L1 and Terminal 4 only.
NONO
NONO
NO
TE:TE:
TE:TE:
TE:
The terminals are identified with white inkThe terminals are identified with white ink
The terminals are identified with white inkThe terminals are identified with white ink
The terminals are identified with white ink.
Be sure to check the switch in all positions and be sure you
have continuity only on the terminals for the selected
position. Lack of continuity or continuity on incorrect termi-
nals designates a defective switch, and it must be replaced.
NOTE: The numbers without circles are the white ink-
stamped numbers.
POSITION TERMINALS
OFF
HIGH 2 FAN L1 and 4
HIGH 1 FAN L1 and 2
LOW FAN L1 and 1
LOW COOLING L1 and C; L1 and 1
HIGH 1 COOLING L1 and C; L1 and 2
HIGH 2 COOLING L1 and C; L1 and 4
HEAT PUMP L1 and H; L1 and 4
B.B.
B.B.
B.
MODEL 59126.502, 630025MODEL 59126.502, 630025
MODEL 59126.502, 630025MODEL 59126.502, 630025
MODEL 59126.502, 630025
First, turn the 20 amp air conditioner breaker to OFF.
Next, remove the wires from the switch. With the switch
in the OFF position, you should not have continuity be-
tween Terminal L1 and any other white numbered termi-
nal.
In the 1st HIGH FAN position you should have conti-
nuity between Terminal L1 and Terminal 1 only.
In the 2nd HIGH FAN position, you should have con-
tinuity between Terminal L1 and Terminal 2 only.
In the LOW FAN position you should have continuity
between Terminal L1 and terminal 4 only.
In the 1st HIGH COOLING position you should have
continuity between Terminal L1 and Terminal H; and Ter-
minal L1 and Terminal 1 only.
In the 2nd HIGH COOLING position, you should have
continuity between Terminal L1 and H; and Terminal L1
and Terminal 2 only.
In the LOW COOLING position, you should have
continuity between Terminal L1 and Terminal H; and Ter-
minal L1 and Terminal 4 only.
In the 1st HIGH HEATING position, you should have
continuity between Terminal L1 and Terminal C; and Ter-
minal L1 and Terminal 1 only.
In the 2nd HIGH HEATING position, you should have
continuity between Terminal L1 and Terminal C; and Ter-
minal L1 and Terminal 2 only.
In the LOW HEATING position, you should have con-
tinuity between Terminal L1 and Terminal C; and Termi-
nal L1 and Terminal 4 only.