Operating instructions

78
6
8
0
F
by Dometic
THERMOSTATTHERMOSTAT
THERMOSTATTHERMOSTAT
THERMOSTAT
The cooling setting determines the temperature at
which the air conditioner will start to operate. The heat
setting determines the temperature at which the heating
system will start to operate.
UPUP
UPUP
UP: Depressing this switch increases the temperature
setpoint.
DOWNDOWN
DOWNDOWN
DOWN: Depressing this switch decreases the tempera-
ture setpoint.
ADJUSTING SETPOINTADJUSTING SETPOINT
ADJUSTING SETPOINTADJUSTING SETPOINT
ADJUSTING SETPOINT
To adjust the setpoint for heating or cooling, press the
MODE button until the arrow on the display indicates the
desired setpoint you which to change, cool or heat. The
display will indicate the current setpoint of the thermostat.
Press UP or DOWN to change the setpoint. Once the new
desired setpoint is displayed, press the MODE button until
the arrow is pointing to ACTUAL. If the thermostat is left in
the COOL or HEAT mode, the display will return to AC-
TUAL in about 3 minutes. After the display returns to
ACTUAL, it takes 15 to 30 seconds for the thermostat to
recognize the changes made to the setpoint.
5F. MODEL 39424.601
AIR CONDITIONER & THERMOSTATAIR CONDITIONER & THERMOSTAT
AIR CONDITIONER & THERMOSTATAIR CONDITIONER & THERMOSTAT
AIR CONDITIONER & THERMOSTAT
This packaged air conditioning heat pump contains a dual
compressor refrigeration system. Each compressor is con-
nected to a separate refrigeration circuit and air system.
The system can be operated with a single compressor when
the cooling requirement is low, or with two compressors
when maximum cooling performance is required.
The first compressor and refrigeration circuit is referred to
as "
Stage 1 CoolingStage 1 Cooling
Stage 1 CoolingStage 1 Cooling
Stage 1 Cooling". The second compressor and refrig-
eration circuit and air system is referred to as "
2nd Stage2nd Stage
2nd Stage2nd Stage
2nd Stage
CoolingCooling
CoolingCooling
Cooling". The first and second stage cooling will operate
as indicated below.
1st Stage Cooling (the first compressor and air sys-1st Stage Cooling (the first compressor and air sys-
1st Stage Cooling (the first compressor and air sys-1st Stage Cooling (the first compressor and air sys-
1st Stage Cooling (the first compressor and air sys-
tem) will operate when:tem) will operate when:
tem) will operate when:tem) will operate when:
tem) will operate when:
The thermostat is calling for cooling.
Power is being supplied by either shoreline or the on-board
generator.
2nd Stage Cooling (the second compressor and air2nd Stage Cooling (the second compressor and air
2nd Stage Cooling (the second compressor and air2nd Stage Cooling (the second compressor and air
2nd Stage Cooling (the second compressor and air
system) will operate whensystem) will operate when
system) will operate whensystem) will operate when
system) will operate when:
The thermostat senses room temperature is two degrees
higher than set point.
The vehicle is being powered by the on-board generator. A
30 amp shoreline by itself will not provide enough power to
operate the 1st and 2nd Stage cooling.
Switching and control of the 1st and 2nd Stage cooling is
automatic. When operating from shoreline, the system
automatically limits operation to 1st Stage cooling only.
When the shoreline is plugged into the on-board generator,
the system automatically allows 1st and 2nd Stage cooling.
However, if powering both systems from the generator and
cooling demand does not required both systems to oper-
ate, Stage 2 will shut down and only Stage 1 will operate.
THERMOSTATTHERMOSTAT
THERMOSTATTHERMOSTAT
THERMOSTAT
This thermostat controls the 12V DC heating and air
conditioning systems. It can control one stage of heat and
two stages of cooling and has an auxiliary heat mode for
gas heating. Changeover from heating to cooling is opera-
tor controlled. The thermostat can not make this change.
Time delay circuits have been incorporated to protect the
heat pump system components. The time delay is 3
minutes between off and on cycles. Thirty seconds delay is
at the turn "ON" of the compressors. This is to allow time
for the generator to stabilized on initial starting. The bal-
ance of the delay (2.5 minutes) occurs when the compres-
sor cycles "OFF". This is to allow the compressor pres-
sures to balance before restarting. There is a thirty second
delay and two degrees between the first and second stage
cooling operation.
OPERAOPERA
OPERAOPERA
OPERA
TIONTION
TIONTION
TION
Your air conditioner is operated from the control panel of
the electronic wall thermostat. When the furnace is con-
nected to this thermostat, it will operate from the same
control panel.