Operating instructions

92
With room temperature BELOW setpoint tempera-
ture, you should NOT have continuity between red wire to
violet, white, black, yellow or blue wires.
With System Switch in COOL, Fan Switch in LOW
AUTO and room temperature ABOVE setpoint tempera-
ture, you should have continuity between red wire (Pin 2) to
black wire (Pin 4) and yellow wire (Pin 5). You should NOT
have continuity between red wire to violet, white or blue
wires. With room temperature BELOW setpoint tempera-
ture, you should NOT have continuity between red wire to
violet, white, black, yellow or blue wires.
With system switch in COOL, Fan Switch in LOW ON
and room temperature ABOVE setpoint temperature you
should have continuity between red wire (Pin 2) to black
wire (Pin 4) and yellow wire (Pin 5). You should NOT have
continuity between red wire to violet, white, or blue wires.
With room temperature BELOW setpoint temperature, you
should have continuity between red wire (Pin 2) to black
wire (Pin 4). You should NOT have continuity between red
wire to violet, white, yellow or blue wires.
With System Switch in COOL, Fan Switch in HI ON
and room temperature ABOVE setpoint temperature you
should have continuity between red wire (Pin 2) to black
wire (Pin 4), yellow wire (Pin 5) and blue wire (Pin 6). You
should NOT have continuity between red wire to violet or
white wires. With room temperature BELOW setpoint
temperature, you should have continuity between red wire
(Pin 2) to black wire (Pin 4) and blue wire (Pin 6). You should
NOT have continuity between red wire to violet, white or
yellow wires.
With System Switch in OFF, Fan Switch in HI AUTO
or LOW AUTO and room temperature ABOVE or BELOW
setpoint temperature, you should NOT have continuity
between red wire to violet, white, black, yellow or blue
wires.
With System Switch in OFF, Fan Switch in LOW ON
and room temperature ABOVE or BELOW setpoint tem-
perature, you should have continuity between red wire (Pin
2) to black wire (Pin 4). You should NOT have continuity
between red wire to violet, white, yellow or blue wires.
With System Switch in OFF, Fan Switch in HI ON and
room temperature ABOVE or BELOW setpoint tempera-
ture, you should have continuity between red wire (Pin 2) to
black wire (Pin 4) and blue wire (Pin 6). You should NOT
have continuity between red wire to violet, white or yellow
wires.
With System Switch in HEAT PUMP, Fan Switch in HI
AUTO and room temperature ABOVE setpoint tempera-
ture, you should NOT have continuity between red wire to
violet, white, black, yellow or blue wires. With room tem-
perature BELOW setpoint temperature, you should have
continuity between red wire (Pin 2) to white wire (Pin 3),
black wire (Pin 4), and blue wire (Pin 6). You should NOT
have continuity between red wire to violet or yellow wires.
With System Switch in HEAT PUMP, Fan Switch in
LOW AUTO and room temperature ABOVE setpoint tem-
perature, you should NOT have continuity between red
wire to violet, white, black, yellow or blue wires. With room
temperature BELOW setpoint temperature, you should
have continuity between red wire (Pin 2) to white wire (Pin
3) and black wire (Pin 4). You should NOT have continuity
between red wire to violet, yellow or blue wires.
With System Switch in HEAT PUMP, Fan Switch in
LOW ON and room temperature ABOVE setpoint tempera-
ture, you should have continuity between red wire (Pin 2) to
black wire (Pin 4). With room temperature BELOW setpoint
temperature, you should have continuity between red wire
(Pin 2) to white wire (Pin 3) and black wire (Pin 4). You
should NOT have continuity from red wire to violet, yellow
or blue wires.
With System Switch in HEAT PUMP, Fan Switch in HI
ON and room temperature ABOVE setpoint temperature,
you should have continuity between red wire (Pin 2) to black
wire (Pin 4) and blue wire (Pin 6). You should NOT have
continuity between red wire to violet, white or yellow wires.
With room temperature BELOW setpoint temperature, you
should have continuity between red wire (Pin 2) to white
wire (Pin 3), black wire (Pin 4) and blue wire (Pin 6). You
should NOT have continuity between red wire to violet or
yellow wires.
With System Switch in AUX HEAT, Fan Switch in HI
AUTO and room temperature ABOVE setpoint tempera-
ture, you should NOT have continuity between red wire to
violet, white, black, yellow or blue wires. With room tem-
perature BELOW setpoint temperature, you should have
continuity between violet wire (Pin 1) and green wire. You
should NOT have continuity between red wire to violet,
white, black, yellow or blue wires.
PIN 1 - VIOLET WIRE
PIN 2 - RED WIRE
PIN 3 - WHITE WIRE
PIN 4 - BLACK WIRE
PIN 5 - YELLOW WIRE
PIN 6 - BLUE WIRE