CoolAir RTX1000, RTX2000 Installation
7.4 Attaching the seal for the cab roof
A
Glue the sealing strip to the cab roof (fig. 7 A).
Follow the contour of the roof hatch opening. The join between the ends of
the seal should be at the back.
Apply a flexible, non-hardening butyl sealant (e.g. SikaLastomer-710) to the
join between the ends of the sealing strip and to the top edge of the sealing
strip (fig. 7 B).
7.5 Fitting the unit in the roof hatch
Place the parking cooler centrally and facing forwards in the roof hatch
opening (fig. 8).
I
A
Fix the parking cooler in place as illustrated (fig. 9).
NOTICE!
Ensure that the surface where the seal between the unit and the cab roof is to
be glued is clean (free of dust, oil, etc.).
NOTE
Once the unit is in position on the vehicle roof, the seal should make contact all
the way round. Only then can a reliable seal be achieved.
NOTICE!
Do not exceed the specified tightening torque under any circumstances. That
is the only way to ensure that the threaded plugs are not pulled out.