Connecting the device MCA1215, MCA1225, MCA1235
22
The pins for the CN2 socket (alarm signal and fan control) are assigned as follows:
The pins for the ESB socket (starter battery connection) are assigned as follows:
Pin in
fig. 9, page 22
Allocation
1 NC (Normally Closed): normally closed contact
2 NO (Normally Open): normally open contact
3 COM (Common): common contact
4 Sleep mode control
5GND
4 5 bridged Sleep mode on
4 5 open Sleep mode off
Pin in
fig. 0, page 22
Allocation
+ VCC (Positive terminal)
GND (Negative terminal)
ESB
0
CN 2
12345