User Manual

EN
Maintaining and cleaning the device MCA1215, MCA1225, MCA1235
26
When you have connected the remote control MCA-RC1 (accessory)
Activate or deactivate sleep mode (noise reduced mode) using the “Sleep
Mode” button (fig. 6 2, page 19).
The fan is not regulated in sleep mode.
The LED (fig. 6 1, page 19) on the MCA-RC1 indicates the operating status (see
following table).
I
10 Maintaining and cleaning the device
A
Disconnect the device from the 230 V power supply.
Disconnect the device from the battery.
Prevent the device from being switched on.
Mode Display Meaning
Sleep mode
activated
Orange, constantly lit Phase 1 to 5
Sleep mode
deactivated
Green, slowly flashing Phase 1 to 4
Green, constantly lit Phase 5
Fault Red, constantly lit Short circuit or defective fuse
Red, quickly flashing Battery or battery charger is overheating
Red, slowly flashing Battery undervoltage or overload
Red, double flash Fan fault
Red, slow double flash Fault at the starter battery connection
NOTE
In the event of a fault (the Status LED is red), refer to chapter “Trouble-
shooting” on page 27).
NOTICE!
Do not use any sharp or hard objects for cleaning since they may
damage the device.
MCA1215-1235--IO--AU.book Seite 26 Donnerstag, 13. Oktober 2016 10:37 10