MCA1215, MCA1225, MCA1235 Technical data
29
14 Technical data
General technical data
MCA12xx
Battery types: Lead-acid, gel, AGM, Dometic eStore
Heat dissipation: Fan
Charge mode: 6-level
Maximum ambient temperature: –20 °C to +50 °C
Storage temperature: –40 °C to +85 °C
Air humidity: 20 – 90 %
Temperature coefficient: ± 0.03 %/°C (0 °C to 50 °C)
Temperature compensation (MCA 12xx): –20 mV/°C (battery sensor)
Vibration
Test type:
Frequency range:
Vibration profile:
Sweep rate:
Duration:
Test axis:
Sinusodial sweep
10 50 Hz
0.35 mm
1oct/min
30 min per axis
Vertical
Voltage insulation: I/P – O/P: 4 kVw
I/P – FG: 1.7 kVw
O/P – FG: 0.7 kVw
Insulation resistance: I/P – O/P: 100 MΩ/500 Vg
Alarm signal: via relay contact
Communication: via LIN-BUS
Sleep mode (noise-reduced mode): via remote control (accessory) or DIP switch
Remote control (accessory): On/off switch, three-colour LED, sleep
mode option