Technical data MCA1215, MCA1225, MCA1235
30
Protective devices
Input data
Testing/certification:
In compliance with the EMC directive
2004/108/EC including 2009/19/EC and
the Low-voltage Directive 2006/95/EC
EN 60335-1
EN 60335-2-29
EN 55022
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2, 3, 4, 5, 6, 8, 11
ENV 50204
In compliance with Australian standard
AS/NZS60335.2.29 and IEC60068.2.6
MCA12xx
Output side short circuit: Current is reduced to 25% of the maximum
current
Overvoltage: 16 V
Protection class: IP21
Battery charger over temperature: 100 °C ± 5 °C (measured internally)
Battery over temperature: 52 °C ± 5 °C (with battery sensor)
MCA1215 MCA1225 MCA1235
Rated input voltage: 200 – 240 Vw
Output factor correction: > 97% (full load)
Input frequency: 50 Hz – 60 Hz
Efficiency at 240 V
?
w 87%
Leakage current: < 1 mA at 240 Vw
Input current at 240 V
?
w 1.07 A 1.8 A 2.8 A
MCA12xx