Operating instructions

11
Grounding/Bonding
All Cabin Comfort Series air conditioning units must be effectively grounded to minimize the
hazard of electric shock and personal injury.
The following are to be observed:
1. AC (alternating current) grounding (green wire) must be provided with the AC power
conductors and connected to the ground terminal (marked “GRND) at the AC power
input terminal block of the unit(s), per ABYC standard E-8, or equivalent.
2. Connections between the vessel’s AC system grounding conductor (green wire) and the
vessel’s DC (Direct Current) negative or bonding system should be made as part of the
vessel’s wiring, per ABYC standard E-9, or equivalent.
3. When servicing or replacing existing equipment that contains a chassis-mounted
“ground” stud, the service person or installer must check the vessel’s wiring for the
existence of the connection required in item 2 above.