RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased Roof Top Unit Used With 3314850.000 Air Distribution Box Description Model Board Built In OR Electronic Control Kit Thermostat Optional Indoor Temperature Sensor 541815, 541816 641815, 641816 Board Built In 3314082.000 CCC2-Blk 3314082.011 CCC2-Wht 457915, 459516 459530, 540315 540316, 640310 640312, 640315 B57915, B59516 B57930 3312020.000 3311931.000-20′ 3311931.
INTRODUCTION This air conditioner/heat pump (hereinafter referred to as “unit” or “product”) is designed and intended for installation on the roof of a Recreational Vehicle (hereinafter referred to as RV) during the time it is manufactured. Read these instructions and highlight the appropriate steps for your particular procedure before starting the installation. This unit can be installed by one person with brief help from additional personnel.
IMPORTANT SAFETY INSTRUCTIONS C. This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. A. Read and follow all safety information and instructions to avoid possible injury or death. Recognize Safety Information Read and understand these instructions before [installing / using / servicing / performing maintenance on] this product. This is the safety alert symbol. It is used to alert you to potential physical injury hazards.
SPECIFICATIONS A. Table - Unit Data Model No. Nominal Capacity (BTU HR) Cooling Electrical Rating 457915.70X 13,500 457915.71X 13,500 120 Vac 60 Hz 1 ph B57915.71X Compressor Compressor Fan Motor Fan Motor Rated Load Locked Rated Load Locked Amps Rotor Amps Rotor Amps Amps Refrigerant R-410A (oz) Minimum Wire Size* AC Circuit Protection ***Installer Supplied Minimum Generator Size** 1 Unit / 2 Units 12 AWG Copper Up to 24' 20 Amp 3.5 kW / 5.0 kW 20 Amp 3.5 kW / 5.0 kW 12.4 63.0 2.
SPECIFICATIONS Model No. Nominal Capacity (BTU HR) Cooling Electrical Rating 641815H75X 13,500 641815H85X 13,500 120 Vac 60 Hz 1 ph 641816.80X Compressor Compressor Fan Motor Fan Motor Rated Load Locked Rated Load Locked Amps Rotor Amps Rotor Amps Amps Refrigerant R-410A (oz) Minimum Wire Size* AC Circuit Protection ***Installer Supplied Minimum Generator Size** 1 Unit / 2 Units 12 AWG Copper Up to 24' 20 Amp 3.5 kW / 5.0 kW 20 Amp 3.5 kW / 5.0 kW 12.7 52.0 2.6 8.5 14.5 12.6 63.
INSTALLATION INSTRUCTIONS A. Choosing Proper Location For Unit This unit is specifically designed for installation on the roof of an RV. When determining your cooling requirements, the following should be considered: ●● Size of RV; ●● Window area (increases heat gain); ●● Amount of insulation in walls and roof; ●● Geographical location where the RV will be used; ●● Personal comfort level required. 1.
INSTALLATION INSTRUCTIONS Dimensions Are Nominal FIG. 4 Model 640312 640315 641815 641816 641835 641915 641916 641935 651815 651816 651916 FIG. 6 21-1/8″ 23-1/8″ 9-1/2″ 40″ 2-5/8″ 29″ Keep These Areas Free Of Obstructions 12″ Dimensions Are Nominal Center Line Of Unit 11-9/16″ 3-7/16″ Front Roof Opening 4″ 4″ 11-9/16″ 21-1/8″ Roof Opening 3-7/16″ 6″ Dimensions Are Nominal FIG.
INSTALLATION INSTRUCTIONS The opening created must be framed to provide adequate support and prevent air from being drawn from the roof cavity. Framing stock 3/4″ or more in thickness must be used. Remember to provide an entrance hole for power supplies, indoor temperature sensor (if applicable), thermostat communication cable, and furnace wires (if applicable) at the front of the opening. See (FIG. 7). a. This supply wire must be located in the front portion of the roof opening. b.
INSTALLATION INSTRUCTIONS 6. (CCC 2 system only) If an Energy Management System (load shed feature) is to be used with the control, two wires must be routed to the roof opening of the zone to be managed. The signal required for this function is normally an open relay contact. When the EMS calls for the compressor to shut off, the relay contacts should close. Make sure that at least 15″ of the EMS wire extends into the roof opening. 7.
INSTALLATION INSTRUCTIONS c. Optional Indoor Temperature Sensor I. Refer to the instructions provided with the indoor temperature sensor for details of installation. d. Thermostat Installation I. Carefully separate the thermostat base plate from the thermostat cover. Insert a small screw driver into the slot on bottom of thermostat and disengage the tab. See (FIG. 11). FIG. 11 cable (3 conductor cable) match the wire colors in the unit wire harness and the wire harness at the LCD SZ electronic control box.
INSTALLATION INSTRUCTIONS Lift and place the unit over the prepared opening using the gasket on the unit as a guide. See (FIG. 14). FIG. 16 Duct Divider FIG. 14 Ceiling Template Lift And Place Front ADB Do Not Slide 3. All models in this manual will use a four (4) bolt pattern for installing the ADB kit. H. 4. Place the electronic control box kit (if applicable) and the ADB kit inside the RV. These boxes contain mounting hardware for the unit and will be used inside the RV.
INSTALLATION INSTRUCTIONS FIG. 17 Models Using Electronic Control Kit Electrical Cord 4. Route the previously run 120 Vac power supply wire through the strain relief and into the junction box. Tighten strain relief making sure not to damage wires. Leave enough wire inside junction box to connect to unit 120 Vac wires. 5. Connect white to white; black to black; and green to green or bare copper wire using appropriate size wire connectors. 6.
INSTALLATION INSTRUCTIONS 5. Hold the clear strain relief cover with the bottom facing upward. See (FIG. 26). FIG. 21 FIG. 26 FIG. 23 Wire Locator Slots Roll Cable Sheath Into Integral Strain Relief Strip Jacket To 1″ FIG. 22 Load Cable into Strain Relief Strain Relief Fingers Hand Bend White And Black Wires Outward 90° Strain Relief Cover (Bottom Facing Upward) Position Black Wire Into Locator Slot 6. Lay wire into locator slots, making sure the black wire is placed into the polarization slot.
INSTALLATION INSTRUCTIONS FIG. 28 J. Attaching Housing Assembly To Strain Relief Cover With Tongue And Groove Pliers, Squeeze Squarely & firmly Between Ribs A & B Strain Relief Cover Duct Divider Installation 1. M easure the ceiling thickness. See (FIG. 17). 2. Cut away the number of rows as indicated in table below. See (FIG. 30). 10″ Minimum Ceiling Thickness Locking Latch Min. Max. 6.0 6.5 5.5 6.0 5.0 # Of Rows To Cut Ceiling Thickness # Of Rows To Cut Min Max. 0 3.5 4.0 5 1 3.
INSTALLATION INSTRUCTIONS L. 2. All Heat Pump Electronic Control Kit Systems a. Plug the outdoor temperature sensor from the unit into the white 2 pin matching connector in the electronic control box. 3. All LCD SZ Electronic Control Kit Systems a. Insert the freeze control sensor into the evaporator coil fins approximately 2″ to 3″ above the bottom of the coil fins and on the left side. See (FIG. 32). Bend fins over sensor to secure in place.
INSTALLATION INSTRUCTIONS Dip switches are in the "OFF" position when shipped from the factory except heat pump and factory installed heat strip models. On these models the appropriate dip switch, heat pump or heat strip, is in the "ON" position from the factory. e. Plug the indoor temperature sensor cable (if applicable) into the 2 pin matching connector protruding from the roof opening or the P4 (white) 2 pin matching connector in the electronic control box. f.
INSTALLATION INSTRUCTIONS g. Dehumidify - Dehumidify is not used on this unit. Leave in the "OFF" position. h. Gen Start selection - Leave in the "OFF" position. i. Install unit electrical box cover and out side plastic shroud or the electronic control box cover whichever applies. j. Repeat this procedure for each additional zone. 2. If your installation includes the optional electric heat kit, install it at this time. Follow the instructions with heat kit package for its installation procedure. 3.
INSTALLATION INSTRUCTIONS Mounting Bolt Pattern Table See (FIG. 40) Mounting Bolt Pattern Table See (FIG.
INSTALLATION INSTRUCTIONS 2. Install two (2) (supplied) sheet metal screws inside return air opening to secure ADB to ceiling template. See (FIG. 43). 3. Install eight (8) (supplied) wood screws inside the front, rear, and side doors to secure ADB to ceiling. See (FIG. 43). FIG. 43 6. Install return air vent grille into the ADB. Slide return air vent grille tab into slot in ADB and rotate up and snap in place. See (FIG. 45). FIG.
INSTALLATION INSTRUCTIONS 2. System Checkout a. Verify that all features of the installed system work. See CCC 2 thermostat Operating Instructions or User's Guide. Check the fan mode, cooling mode, heating mode (if applicable), and furnace mode (if applicable) operation. If features do not work, disconnect the 120 Vac and 12 Vdc power supplies and verify that all wiring is correct and that the correct dip switches have been set to the "ON" position. Q. FIG.
GENERAL INFORMATION A. Frost Formation On Cooling Coil C. Frost on a small portion of the coil is not unusual. Under certain conditions, ice may form on the evaporator coil. This is indicated by very cold output at very low air speed and the icing can be seen through the air inlet hole with the filter removed. If this should occur, inspect the filter and clean if dirty. Make sure air vents are open and not obstructed. Units have a greater tendency to frost when the outside temperature is relatively low.
WIRING DIAGRAMS A. Simple RV Wiring Diagram FIG.
WIRING DIAGRAMS B. Unit Wiring Diagrams 4. 540315 & 540316 Unit Wiring Diagram 1. 457915, B57915, B57935U, B57935Y, 459516, B59516, 459530, B59530, B59536U, & B59536Y Unit Wiring Diagram FIG. 51 FIG. 48 5. 541915 & 541916 Unit Wiring Diagram FIG. 52 2. 459186 & B59186 Unit Wiring Diagram FIG. 49 6. 551816, 651815, & 651816 Unit Wiring Diagram FIG. 53 3. 459196 & B59196 Unit Wiring Diagram FIG.
WIRING DIAGRAMS 7. 551916 Unit Wiring Diagram 10. 641915 & 641916 Unit Wiring Diagram FIG. 54 FIG. 57 3$66(' ',(/(&75,& %/. /,1( *51 <(/ ($57+ :+7 1(87 3$66(' ',(/(&75,& 9$& += 2 86( &233(5 &21'8&7256 21/< %5 5 2/ 6 & 5(' %/8 :+7 37&5 237 %5 %/. 02725 :+7 5(' . 5(/$< 12 5(9(56,1* 9$/9( %/. 287'225 7(03 6(1625 - )5((=( 6(1625 - &20
WIRING DIAGRAMS C. Electronic Control Kit Wiring Diagrams 3. 3313189.049 & 3313189.056 LCD SZ Electronic Control Kit Wiring Diagram Cool/Furnace/HS 1. 3312020.000 CCC 2 Electronic Control Kit Wiring Diagram FIG. 62 FIG. 60 4. 3313189.064 & 3313189.072 LCD SZ Electronic Control Kit Wiring Diagram Cool/Furnace/HP 2. 3313189.000 & 3313189.015 LCD SZ Electronic Control Kit Wiring Diagram Cool/Furnace FIG. 61 FIG.