Hobs and Combinations Installing the device
19
The opening in cabinet must be
level from side to side and front to rear
The cabinet opening must be constructed so that no combustible material can be
placed next to the cooktop sides.
The maximum depth of cabinets installed above the cooking top must be 13 in
(330 mm).
The device area has to kept clear and free from combustible materials, gasoline
and other flammable vapors and liquids.
The flow of combustion and ventilation air must not be obstructed.
Leak testing of the device shall be conducted according to the manufacturer's
instructions.
6.1 Selecting the installation location
When selecting the installation location, observe the following instructions:
Consider the volume of air required for combustion (chapter “Technical data” on
page 25).
During operation, there must be air vents with a cross-section of at least 23.25 in²
(150 cm
2
) in the installation room.
Make sure that minimum distances (fig. 2, page 4) are observed.
Ensure that there are no drafts at the installation location.
6.2 Installing the device
Create a cutout according to the installation drawing:
PI8022: fig. 3, page 4
CE99-ZF: fig. 4, page 5
CE99-DF: fig. 5, page 5
Affix the device to the worktop using the screws (fig. 6, page 6 – fig. 7,
page 6).