CFX-28-CFX-65--O-EN-AUSv2.book Seite 3 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ Please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it. The manufacturer cannot be held liable for damage resulting from improper usage or incorrect operation. Contents 1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . .
CFX-28-CFX-65--O-EN-AUSv2.book Seite 4 Dienstag, 3. April 2018 8:42 08 Explanation of symbols CFX28 – CFX65DZ 8 Cleaning and maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 10 Guarantee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 11 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CFX-28-CFX-65--O-EN-AUSv2.book Seite 5 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ 2 Safety instructions 2.1 General safety ! WARNING! ! A EN Safety instructions • Do not operate the cooling device if it is visibly damaged. • If this cooling device's power cable is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards. • This cooling device may only be repaired by qualified personnel.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 6 Dienstag, 3. April 2018 8:42 08 Safety instructions • Never pull the plug out of the socket by the cable. • If the cooling device is connected to the DC outlet: Disconnect the cooling device and other power consuming devices from the battery before connecting a quick charging device. • If the cooling device is connected to the DC outlet: Disconnect the cooling device or switch it off when you turn off the engine. Otherwise you may discharge the battery.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 7 Dienstag, 3.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 8 Dienstag, 3. April 2018 8:42 08 Accessories 4 CFX28 – CFX65DZ Accessories Available as accessory (not included in scope of delivery): Designation Ref. no.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 9 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ 5 Intended use Intended use The cooler is suitable for cooling and freezing foods.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 10 Dienstag, 3. April 2018 8:42 08 Function description 6.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 11 Dienstag, 3.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 12 Dienstag, 3.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 13 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ Operation 7 Operation 7.1 Before initial use I NOTE Before starting your new cooler for the first time, you should clean it inside and outside with a damp cloth for hygienic reasons (please also refer to the chapter “Cleaning and maintenance” on page 26).
CFX-28-CFX-65--O-EN-AUSv2.book Seite 14 Dienstag, 3. April 2018 8:42 08 Operation CFX28 – CFX65DZ Selecting the temperature units Temperature display units can be switched between Celsius and Fahrenheit as follows: ➤ Switch on the cooler. ➤ Press the “SET” button (fig. 3 4, page 11) twice. ➤ Use the “UP +” (fig. 3 7, page 11) or “DOWN –” (fig. 3 6, page 11) buttons to select Celsius or Fahrenheit. ✓ The selected temperature units then appear in the display for a few seconds.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 15 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ Operation Using the fused DC plug A NOTICE! Danger of damage! For protection of the device the DC cable supplied includes a fuse inside the plug. Do not remove the fused DC plug. Only use the DC cable supplied. ➤ Plug the DC connection cable (fig. 1 2, page 7) into the DC voltage socket of the cooler (fig. 4 3, page 12). ➤ Connect the connection cable to the DC power outlet. Connecting to an AC power supply (e.g.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 16 Dienstag, 3. April 2018 8:42 08 Operation 7.4 CFX28 – CFX65DZ Using the battery monitor The device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board DC supply. If the cooler is operated when the vehicle ignition is switched off, the cooler switches off automatically as soon as the supply voltage falls below a set level.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 17 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ 7.5 A Operation Using the cooler NOTICE! Danger of overheating! Ensure at all times that there is sufficient ventilation so that the heat that generated during operation can dissipate. Ensure that the ventilation slots are not covered. Make sure that the device is sufficiently far away from walls and other objects so that the air can circulate. ➤ Place the cooler on a firm foundation.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 18 Dienstag, 3. April 2018 8:42 08 Operation CFX28 – CFX65DZ 7 1 CFX50W, CFX65W 8 1 2 CFX65DZ ! 18 CAUTION! Health hazard! CFX65DZ: If the temperature in the freezer compartment (fig. 8 1, page 18) is very low (–22 °C), the temperature range in the cooling department (fig. 8 2, page 18) can be below freezing as well.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 19 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ I Operation NOTE Displayed temperature • CFX28, CFX35W, CFX40W, CFX50W, CFX65W: The temperature displayed is that of the large interior compartment (e.g. CFX50W, CFX65W: fig. 7 1, page 18). • CFX65DZ: – With fridge/freezer divider in: The temperature displayed is that of the freezer compartment (fig. 8 1, page 18).
CFX-28-CFX-65--O-EN-AUSv2.book Seite 20 Dienstag, 3. April 2018 8:42 08 Operation 7.7 CFX28 – CFX65DZ Enabling WiFi signal for optional app (all except CFX28 and CFX65DZ) The cooler can be controlled via WiFi using an app that you can install on a compatible device. The app has control, display and alarm functions. For further information go to the Dometic website for your country (see back page). Note that the app may not be available in your country.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 21 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ Operation Resetting the WiFi to factory settings In case you have personalized the WiFi settings of your cooling device using the WiFi app and forgotten your password, you can reset to the factory settings as follows: ➤ Press the “SET” button (fig. 3 4, page 11) five times. ➤ Hold the “UP +” (fig. 3 7, page 11) button for at least five seconds.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 22 Dienstag, 3. April 2018 8:42 08 Operation 7.9 CFX28 – CFX65DZ Using the emergency switch (where fitted) The emergency switch (fig. 5 1, page 12) is located below the control panel on all models except CFX28 where it is located above the power inlet sockets. For normal operation the switch is in the “NORMAL USE” position.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 23 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ 7.11 Operation Switching off the cooler ➤ Empty the cooler. ➤ Switch the cooler off. ➤ Pull out the connection cable. If you do not want to use the cooler for a longer period of time: ➤ Leave the cover slightly open. This prevents odour build-up. 7.12 Defrosting the cooler Humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 24 Dienstag, 3. April 2018 8:42 08 Operation CFX28 – CFX65DZ 7.13 Replacing the AC fuse D DANGER! Danger of electrocution! Disconnect the power supply and the connection cable before you replace the device fuse. ➤ Disconnect the power supply to the device. ➤ Pull off the connection cable. ➤ Pry out the fuse insert (fig. 4 2, page 12) with a screwdriver. ➤ Replace the defective glass fuse with a new one that has the same type and rating (4 A, 250 V).
CFX-28-CFX-65--O-EN-AUSv2.book Seite 25 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ 7.15 Operation Replacing the light PCB 0 1. + – ° SET 2. 3. ➤ Disconnect the power supply to the device. ➤ Pry out the transparent cover with a screwdriver (1). ➤ Unscrew the PCB mounting screws (2). ➤ Pull out the plug from the PCB (3). ➤ Replace the defective light PCB with a new one. ➤ Fit new PCB using reverse of removal instructions. ➤ Press the transparent cover back into the housing.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 26 Dienstag, 3. April 2018 8:42 08 Cleaning and maintenance 8 ! A CFX28 – CFX65DZ Cleaning and maintenance WARNING! Always disconnect the device from the power supply before you clean and service it. NOTICE! Risk of damage • Never clean the cooler under running water or in dish water. • Do not use abrasive cleaning agents or hard objects during cleaning as these can damage the cooler. ➤ Occasionally clean the device interior and exterior with a damp cloth.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 27 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ Troubleshooting Fault Possible cause Suggested remedy When operating from the DC outlet: The ignition is on and the device is not working and the LED is not lit. The DC outlet is dirty. This results in a poor electrical contact. If the plug of your cooler becomes very warm in the DC outlet, either the DC outlet must be cleaned or the plug has not been assembled correctly.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 28 Dienstag, 3. April 2018 8:42 08 Guarantee 10 CFX28 – CFX65DZ Guarantee The statutory warranty period applies. If the product is defective, please contact the manufacturer's branch in your country (see the back of the instruction manual for the addresses) or your retailer.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 29 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ 12 Technical data Technical data Ref. no.: CFX28 CFX35W CFX40W 9105306503 9105306495 9105306496 Connection voltage: Rated current: 12/24 Vg and 100 – 240 Vw 12 Vg: 6.5 A 24 Vg: 3.2 A 100 Vw: 0.75 A 240 Vw: 0.32 A Cooling capacity: 12 Vg: 7.0 A 24 Vg: 3.2 A 100 Vw: 0.86 A 240 Vw: 0.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 30 Dienstag, 3. April 2018 8:42 08 Technical data Ref. no.: CFX28 – CFX65DZ CFX50W CFX65W CFX65DZ 9105306497 9105306498 9105306499 Connection voltage: Rated current: 12/24 Vg and 100 – 240 Vw 12 Vg: 7.8 A 24 Vg: 3.6 A 100 Vw: 0.95 A 240 Vw: 0.46 A Cooling capacity: 12 Vg: 8.2 A 24 Vg: 3.8 A 100 Vw: 1.0 A 240 Vw: 0.48 A +10 °C to –22 °C (+50 °F to –8 °F) Category: 1 Energy efficiency class: Energy consumption: 12 Vg: 5.5 A 24 Vg: 2.6 A 100 Vw: 0.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 31 Dienstag, 3. April 2018 8:42 08 CFX28 – CFX65DZ I Technical data NOTE If the ambient temperature is above +32 °C (+90 °F), the minimum temperature cannot be attained. Test/certificates: 4 The coolant circuit contains R134a.
CFX-28-CFX-65--O-EN-AUSv2.book Seite 32 Dienstag, 3. April 2018 8:42 08 BENELUX Dometic Branch Office Belgium Zincstraat 3 B-1500 Halle +32 2 3598040 +32 2 3598050 Mail: info@dometic.be BRAZIL Dometic DO Brasil LTDA Avenida Paulista 1754, conj. 111 SP 01310-920 Sao Paulo +55 11 3251 3352 +55 11 3251 3362 Mail: info@dometic.com.br DENMARK Dometic Denmark A/S Nordensvej 15, Taulov DK-7000 Fredericia +45 75585966 +45 75586307 Mail: info@dometic.