Operating Manual
Table Of Contents
- 1 Explanation of symbols
- 2 Safety instructions
- 3 Scope of delivery
- 4 Accessories
- 5 Intended use
- 6 Function description
- 6.1 Scope of functions
- 6.2 Operating and display elements
- 7 Operation
- 7.1 Before initial use
- 7.2 Energy saving tips
- 7.3 Reversing the lid opening direction
- 7.4 Connecting the cooler
- 7.5 Using the cooler
- 7.6 Using the display
- 7.7 Locking/unlocking the display
- 7.8 Selecting the temperature units
- 7.9 Setting the temperature
- 7.10 Using the battery protection
- 7.11 Setting the display‘s brightness
- 7.12 Switching on or off the compartments (only CFX 3 75DZ, CFX 3 95DZ)
- 7.13 Using the ice maker (only CFX 3 55IM)
- 7.14 Downloading the CFX3 app
- 7.15 Setting the Bluetooth signal and connecting to the app
- 7.16 Setting the WiFi signal and connecting to the app
- 7.17 Changing CFX name and password in the app
- 7.18 Resetting the app password (WiFi only)
- 7.19 Resetting to factory settings
- 7.20 USB port for power supply
- 7.21 Defrosting the cooler
- 7.22 Replacing the AC fuse
- 7.23 Replacing the DC fuse
- 7.24 Replacing the DC plug fuse
- 7.25 Replacing the light PCB
- 8 Cleaning and maintenance
- 9 Troubleshooting
- 10 Warranty
- 11 Disposal
- 12 Technical data
EN
Troubleshooting CFX3
34
Alert messages
E.g. see
fig. n A, page 14.
The display does not
respond to keystrokes.
The display is locked. Unlock the display, see chapter “Lock-
ing/unlocking the display” on page 26.
The app cannot con-
trol the device.
Bluetooth or WiFi is not
connected.
Connect Bluetooth, see chapter “Set-
ting the Bluetooth signal and connecting
to the app” on page 30, or Connect
WiFi, see chapter “Setting the WiFi sig-
nal and connecting to the app” on
page 30
The display shows an
alert message or
warning code.
– See table below.
Alert message Description Possible cause Suggested remedy
!ALERT - Lid open
> 3min
Lid open more
than 3 minutes
• Lid not fully
latched
•Internal fault
• Check lid latched fully
• Authorised repair centre
inspection required
!ALERT - Voltage
low
The device has
stopped working
on DC due to low
voltage
• Insufficient supply
voltage
• Battery voltage is
too low
• Battery protec-
tion is set too high
• Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
• Test the battery and
charge as needed
• Select a lower battery
protection setting
The device has
stopped working
on DC due to
abnormally high
voltage >31.5 V
(unlikely event –
for electronics
protection only –
uses same alert
message as low
voltage above)
• Wrong DC supply
voltage
specification
• Faulty supply
voltage
•Internal fault
• Ensure DC supply volt-
age specification
matches CFX3 product
rating label
• Check DC voltage sup-
ply & repair or replace if
faulty
• Authorised repair centre
inspection required
Fault Possible cause Suggested remedy
CFX3_OPM_APAC(en).book Seite 34 Mittwoch, 24. Juni 2020 11:07 11