Operating instructions

Connecting the refrigerator CombiCool CAS-60
42
Connecting the refrigerator to an outside supply
Note!
Only use the WAECO hose with quick coupling (optional accesso-
ry).
Note the norms EN 732 and EN 1949.
Make sure the pressure is limited to 30 mbar.
Connect one end of the hose to the port (fig. 4 1, page 5) on the refrig-
erator by turning the union nut anticlockwise.
Use an open-end spanner (17 mm) to turn the nut and a 13 mm spanner
to hold it.
Take the cap off the coupling (fig. 4 2, page 5).
Push the sleeve into the coupling (fig. 4 2, page 5) until you hear it
catch.
Open the valve on the coupling (fig. 4 2, page 5).
Open the gas tank valve.
Check all connections with leak spray.
There are no leaks if no bubbles form.
Put the refrigerator into operation (chapter „Putting the refrigerator into
operation" on page 44).
To disconnect the gas:
Close the valve on the coupling (fig. 4 2, page 5).
Disconnect the gas hose.
To do this, push the sleeve towards the handle with the valve closed.
Put the cap on the coupling (fig. 4 2, page 5).
CAS-60.book Seite 42 Dienstag, 10. Oktober 2006 3:41 15