Operating Instructions and Installation Instructions

MAINTENANCE USE
INSTALLATION
19
ENG LISH
The gas supply pipe connected to the appliance must be a rigid metal pipe with sealed fittings. It is possible to fit a
flexible hose, however, in this case the following conditions must be respected:
a) The hose can be accessed easily for inspection;
b) The hose must be protected against coming into contact with parts which heat up (EG: parts underneath the burners);
c) The hose must be protected against being damaged (twisting, pulling, trapping,….);
d) The hose must be protected against being trapped by moving parts (e.g. drawers);
e) The hose must not have a length over 1.5 m;
f) The hose must be replaced before its expiry date;
Once the appliance has been connected to the gas supply check for gas leaks utilising a non-corrosive fluid.
Do not use a water and soap solution. NEVER USE A FLAME TO CHECK FOR GAS LEAKS.
This appliance is designed for running off the following types of gas at the corresponding operating pressures. The gas
category (or categories) of the appliance is given on the specifications label affixed to the appliance.
CONNECTING TO GAS SUPPLY
CHECK THESE SPECIFICATIONS BEFORE CONNECTING THE APPLIANCE TO THE
GAS CYLINDER /BOTTLE. THE PRESSURE REGULATORS CONNECTED BETWEEN
THE GAS CYLINDER AND APPLIANCE MUST CONFORM WITH THE CATEGORIES
GIVEN IN THE BELOW TABLE.
CATEGORY AND COUNTRY OF DESTINATION
I3B/P(30)
AT BE DE DK FI GB NL NO PT SE SI
I3+ (28-30/37)
BE CH ES FR GB IE IT PT SI
GAS PRESSURE
30 mbar Butane (G30)
30 mbar Propane (G31)
28-30 mbar Butano (G30)
37 mbar Propano (G31)
MODEL TOTAL RATED
THERMAL CAPACITY
REQUIRED VOLUME OF AIR
FOR COMBUSTION
kW - gr/h m
3
/h
CU322 - CU322M 4,0 - 291 8,0
CU333 - CU333M 4,4 - 320 8,8
CU403PE - CU404PEMW - CU407PEMW 4,6 - 335 9,2
CU354MK 5,1 - 371 10,2
CU352M 5,3 - 386 10,6
CU325 - CU325M - CU404PE - CU405PEMW 5,8 - 422 11,6
CU335 - CU335M - CU402PE - CU414PE 6,2 - 451 12,4
403 - CU351MK - CU404MW - CU407MW 6,4 - 466 12,8
CU433 - CU433M - CU433ML 6,6 - 480 13,2
CU300 - CU300M 6,8 - 495 13,6
CU311 - CU311M 7,2 - 524 14,4
CU400BPE - CU400PE - CU401PE 7,4 - 539 14,8
404 - CU405MW 7,6 - 553 15,2
402 - 414 8,0 - 582 16,0
400 - 400B - 401 9,2 - 669 18,4
DURAWHEN INSTALLING AND CONNECTING THE APPLIANCE TO THE GAS
SUPPLY, ENSURE THAT THE GAS SUPPLY HOSE IS NOT TWISTED, STRETCHED OR
SUBJECTED TO ANY FORM OF STRAIN WHICH COULD CREATE A HAZARD.