miniCool DS 200 DS 300 DS 400 Type: DS20-60 DS 600 Free-standing and Built-in under version Operating Instructions 207.5368.
Please read these operating instructions carefully before putting the refrigeration unit into operation. If you later sell or dispose of it, please ensure that the new owner receives these operating instructions. Please follow the installation details below carefully Guarantee is valid for products installed as described only. (See chapter 4.1) Thank you for choosing our appliance. We are sure it will provide you with trouble-free use.
CONTENTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Unpacking View of the appliance Cleaning Positioning the appliance 4.1. Installation instruction 4.1.1. Built-in versions 4.1.2. Freestanding versions Using the appliance 5.1. Initial operation 5.2. Temperature regulation 5.3. Cooling unit control (CUC) Useful suggestions Defrosting, cleaning and maintenance 7.1.
1. Unpacking After removal from the cardboard packaging, make sure the appliance is not damaged. If you find damage to the appliance resulting from transport, report it immediately to the transportation firm. All model are available in freestanding and built-in version. BI in the modelname refers for the built-in version and FS for the freestanding version. Please check your product version (figure 1.) and follow the relevant instructions about the installation and operation.
11 11 DS 400 DS 600 Figure 2. 1. 2. 3. 4. 5. 6. Door lock (if available) Door Evaporator Thermostat knob Cooling unit cover Interior light 7. 8. 9. 10. 11. Shelves Footframe Air-sensor Door racks Evaporator-sensor IN CASE IF YOUR REFRIGERATOR IS EQUIPPED WITH LOCK, DOMETIC RT DO NOT ACCEPT LIABILITY FOR LOSS OR DAMAGE OF KEYS. HOWEVER A COMPLETE LOCK CAN BE SUPPLIED. 3. Cleaning Clean the refrigerator thoroughly at intervals, as necessary.
The miniCool can be screwed to the furniture using the fittings at the bottom. Drive in the screws (figure 3). Figure 3. 4.1.2. Freestanding versions These versions are intended for freestanding use. Cooling unit covers protect the hot parts of the cooling units. Foot frames with grilles ensure sufficient ventilation. These models can be also build in into the furnitures with sliding hinges or simply be pushed into a given space. In this case please take into the consideration items listed below.
5.3. Cooling unit control (CUC) The electronic checks the function after every defrosting period (every 24 hours) by measuring the evaporator temperature drop. If it registers a problem the refrigerator will shut down and the LEDs of the interior light will begin to flash continously. If this happens you should check whether the refrgerator has been overloaded, that the door was properly closed, that the cooling unit ventilation is correct and that the refrigerator is levelled.
10. Replacing the decorative door panel (Fig. 11.) 11.1. Fitting up the handle (fig. 12., 13.) If the refrigerator is furnished with handle, it is the handle that should be first removed at the change of the door panel. Remove the mounter screws (1) of the forehead panel (3). Remove rosette (2) (in case of with lock version fridge). Lift and remove the forehead panel.(3) Slide the decorative panel (4) out of the door frame and insert the new panel (thickness max. 2 mm).
13. Putting into operation Technical data: Model Type Gross volume Mains operation Input Energy consumption Climate class Absorber Solution DS 200 DS20-60 22,5 litre 120 V (AC) 65W 0.74 kWh/24h SN 147g H2O + 98 g NH3 DS 300 DS20-60 28,1 litre 120 V (AC) 65W 0,76 kWh/24h SN 151g H2O + 101 g NH3 13.1. Connecting to electrical mains The appliance may only be operated from nominal voltage mains as shown on the data plate.