Problem
The appliance does not
cool sufficiently
The appliance does not
cool at all
Possible cause
Thermostat control is set too low
Too much food to be cooled was put in
Door is not shut properly.
Refrigerator not level
Internal air circulation is restricted.
External air circulation is restricted.
CUC system stopped the operation
Plug is not connected to the mains
socket properly.
There is no voltage in the mains socket
Solution
Set to a higher position
Put in less food to be be cooled
Check if the door is shut
Level refrigerator
Provide inside cool air circulation.
Provide outside air circulation.
See operating instruction 5. 2.
Check if the connection is proper.
Check if there is voltage.
(eg. Connect a lamp to the socket)
If after checking all the above points, the refrigerator is
still not working satisfactorily, contact your nearest
service engineer. State the problem, model, product-
and serial-number.
(Details of the model, product- and serialnumber are
to be found on the data label in the top left of the
inside compartment.)
Refrigerators until serial number 637xxxxx are
equipped with overheating protection on the cooling
unit. An authorised service technician can check
whether this has been triggered or not.
Refrigerators from serial number 637xxxxx, instead of
having overheating protection, are equipped with a
second (evaporator) sensor.
In the event of a fault developing, contact your nearest
Service Centre-see local telephone directory.