of 2°F (1.1°C) is adequate for maintaining a comfortable temperature variation around the desired set point. If you desire less
variation in temperature, set this parameter to 1°F (0.55°C).
P-24: Moisture Mode Minimum Temperature
(Available only in software revision B23 and newer.) This parameter is the minimum room temperature in Fahrenheit for
which Moisture Mode will run a cooling cycle to remove moisture from the air. If the room temperature is below this parameter
setting, Mositure Mode will run a heating cycle instead. By default, this parameter is 50°F (10°C), and it can be adjusted
between 40°F (4.4°C) to 75°F (23.9°C). Please refer to the description of “Moisture Mode” on page 6 for more information on
how Moisture Mode functions and utilizes this parameter.