Operation Manual

Elite Control Operations Manual Read This Manual Before Proceeding
L-2230 ENGLISH 1
INTRODUCTION
The Elite Control is a microcontroller-based unit designed for use with direct expansion, reverse-cycle air conditioning systems.
READ THIS MANUAL BEFORE PROCEEDING
Read this manual completely before you proceed with the installation and operation of the Elite. If you have questions or require
assistance with your Elite control, contact the Dometic Marine Service Department at +1 954-973-2477.
The Elite is covered under existing Marine Air Systems Warranty Policy. Incorrect installation, neglect and system abuse are not
covered under Marine Air Systems warranty policy.
FEATURES
STANDARD
User-friendly five-button display panel requires no manual for basic operation.
Five-volt logic and microcontroller located in the display.
Three-digit, seven-segment display panel indicates degrees Fahrenheit or degrees Celsius.
Automatic and three programmable manual fan speeds.
22 programmable parameters for custom installations.
High- and low-refrigerant-pressure sensor inputs.
Moisture Mode for controlling relative humidity.
De-Icing cycle to prevent evaporator coil icing.
Programmable compressor staging delays.
Universal 115/230 volt, 50/60 Hz AC power supply.
Nonvolatile memory retains settings without batteries.
Programmable display-brightness control.
Programmable failsafe modes.
Fits Vimar® switch bezels.
OPTIONAL
Outside air temperature sensor.
Alternate air temperature sensor.
Pump Sentry water sensor.
Electric heating control capabilities.
CAN-bus network capability (available in software revision A16 or newer).
Air Filter Cleaning or Replacement Timer (available in software revision A15 or newer).
Low-Voltage Monitor (available in software revision A15 or newer).
This manual provides all necessary information for proper installation and operation of the Elite. Poor installation and
misunderstood operating parameters will result in unsatisfactory performance and possible failure.
DESCRIPTION OF CONTROL
See Figure 1 and Table 1 on page 2 to identify all parts of the control.
POWER
Press the Power Button once to engage the system. The display is blank when the system is off and indicates current room
temperature when the system is on.
MODE SELECTION
Press and release the Mode Button until the desired Mode LED is illuminated.
SET POINT
Press the Up or Down button to set the desired room temperature. To view the set point, momentarily press and release the Up
or Down button.