FREEZER/REFRIGERATOR F400 0402 Operating Instructions 207.5082.
Please read these operating instructions carefully before putting the refrigeration unit into operation. If you later sell or dispose of it, please ensure that the new owner receives these operating instructions. Thank you for choosing our appliance. We are sure it will provide you with trouble-free use.
CONTENT S 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Unpacking View of the appliance Cleaning Positioning the appliance Using the appliance 5.1. From electrical mains 5.2. From vehicle battery 5.3. From bottled gas Useful suggestions Defrosting, cleaning and maintenance Warranty and customer service Putting into operation, technical data 9.1. Connecting to electrical mains 9.2. Connecting to vehicle battery 9.3. Connecting to as cylinder 9.4.
1. Unpacking After removal from the cardboard packaging, make sure the appliance is not damaged. If you find damage to the appliance resulting from transport, report it immediately to the transportation firm. 2. View of the appliance Figure 1. 4 1. insulated casing 3. control panel 2. insulated lid 4.
3. Cleaning Clean both the inside and outside of the appliance before putting it into use. To do so, use a soft towel, lukewarm water and a non-abrasive detergent. Ensure water does not enter the rear cover grille or the control elements. Afterwards, wipe the appliance with a clean towel and cleanwater, and then wipe it dry. To avoid damage, do not use soap, soda or abrasive cleaners. 4.
5.2. Operating from 12 Volt vehicle battery Make sure the voltage shown on the data plate of the appliance matches the voltage of the vehicle battery (12V). In 12V operation, the appliance runs continuously without temperature control. The appliance is supplied with a matching pair of 12 Volt MALE + FEMALE plugs (see 9,2 connection to vehicle power source). For 12V operation, make sure, if the engine is not running, that the plug must be disconnected (see fig. 7).
6. Useful suggestions When setting out on a trip, run the appliance on 230 V (in thermostat setting between min and max for cooling and "max" for freezing) for 24 hours prior to departure. Place food in a precooled condition into the appliance. Frost forms on the evaporator panel when in operation. When opening the lid or putting in food, some of this frost melts and collects in the form of water on the bottom of the appliance. Wipe the water off occasionally using a sponge.
. Warranty and customer service 9. Putting into operation Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable in the country concerned. For warranty or other servicing, such as spare-parts, please contact our Dometic Service Network. The warranty does not cover any damage due to improper use. The warranty does not cover any modifications to the appliance or the use of non-original Dometic spareparts.
One possible way of the connecting can be seen (on figure 6.) A - fuse holder with 16A fuse B - wire ties C - positive battery cable If the 2,5m long cable proves to be short, up to 4m length 2,5mm2 ;while up to 6m length 4,0mm2 sectioned cable must be used. Pay attention to the voltage values noted on the rating label and on a label placed below the female socket! Figure 6. The 12V operation is turned on by connecting the plug and cut off by disconnecting the plug.
9.4 Connection of gas supply (The following instructions refer in the main to coolers manufactured in the United Kingdom. For other countries please refer to your supplier.) Always connect in the following sequence: GAS BOTTLE → PRESSURE-REGULATOR → → APPLIANCE. To connect the appliance to the pressure-regulator an APPROVED GAS TUBING should be used. This should be minimum in length - have an inside dimension of 8mm and be marked BS3212/2/8.
10. Environmental protection information The appliance does not contain any CFCs/HCFCs. Ammonia (natural hydrogen and nitrogen compound) is used as a refrigerating agent in the refrigeration unit. The ozone-friendly cyclopentane is activated as a motive agent for the PU foam insulation. Sodium chromate is used for corrosion protection (less than 2 weight % of the coolant). 11. Recycling After unpacking the appliance, the packing materials should be delivered to a local collection site.