User manual

9
One possible way of the connecting can be seen (on
figure 6.)
A - fuse holder with 16A fuse
B - wire ties
C - positive battery cable
If the 2,5m long cable proves to be short, up to 4m
length 2,5mm
2
;while up to 6m length 4,0mm
2
sectioned cable must be used.
Pay attention to the voltage values noted on the rating
label and on a label placed below the female socket!
The 12V operation is turned on by connecting the plug
and cut off by disconnecting the plug.
Push the fixing tab with a screw-driver as can be seen
(in figure 7). After that the plug can be disconnected.
9.3 Connecting to gas cylinder
Make sure no other energy source is connected
(230V, 12V).
The unit must not be connected to town or natural gas
pipelines. It is only suitable for use with
propane/butane gas (e.g. Calor Gas, Camping Gaz,
Caravangas, etc.).
The freezer / refrigerator is equipped for a specific
gas-pressure, corresponding to the standard pressure
of the country in which it is sold. The rating-plate
states the pressure that is correct. It is important that
a non-adjustable pressure-regulator is used to reduce
the pressure in the gas cylinder to the operating
pressure specified on the rating-plate. No other
pressure may be used.
Needle valve-operated gas control taps are NOT
suitable for use with this appliance and must not be
used as a substitute for a pressure regulator.
Figure 6.
Figure 7.