Operation Manual

EN
Maintenance of the roof air conditioner FreshJet
36
Clean the housing of the roof air conditioner and the air outlet unit occasionally
with a damp cloth.
Regularly remove leaves and other dirt from the ventilation grilles (fig. 5 1,
page 6) of the roof air conditioner. Make sure you do not damage the grilles in
the process.
Clean the remote control with a slightly damp cloth from time to time. We
recommend using a cleaning cloth for glasses to clean the display.
11 Maintenance of the roof air conditioner
!
WARNING!
Any other maintenance work to that which is described here may only
be carried out by qualified personnel who are familiar with the risks
involved when handling refrigerant and air conditioning systems as well
as the relevant regulations.
Interval Inspection/maintenance
Regularly Check the condensation water drainage:
Check whether the condensation water drainage channels
(fig. 6 1, page 6) at the sides of the roof air conditioner are clear
and the condensation water is able to escape.
Regularly Clean the filter of the air discharge unit (fig. 7, page 7):
Manually take off the filter cover (1).
Remove the filter (2).
Clean the filter (2) with a detergent solution and let it dry.
Put the dry filter (2) back in.
Put the cover (1) back on.
Once per year Check the profile seals:
Check the seal between the roof air conditioner and the roof of the
vehicle for cracks and other damage.
Once per year Have the heat exchanger serviced:
Have the heat exchanger of the roof air conditioner serviced by
specialist workshop.
FreshJet-ADB2015-O-16s.book Seite 36 Donnerstag, 1. Februar 2018 12:02 12