Product Manual

EN
a
Troubleshooting Harrier series
24
Low air output The air intake grilles are blocked or
obstructed.
Remove any leaves and other
dirt from the ventilation grilles
of the roof air conditioner.
The fan is defective. Contact an authorised service
agent or Dometic.
Water enters the
vehicle.
The condensation water drainage
openings are clogged up.
Clean the drainage openings
for condensation water.
The seals are damaged. Contact an authorised service
agent or Dometic.
Roof air
conditioner does
not switch on.
No supply voltage (240 V AC)
connected.
Check the power supply.
The voltage is too low (under
200 V AC).
Contact an authorised service
agent or Dometic.
The voltage converter is defective.
One of the temperature sensors is
defective.
The electrical fuse of the power
supply is too low.
Check the electrical fuse of
the power supply.
Roof air
conditioner does
not switch off.
One of the temperature sensors is
defective.
Contact an authorised service
agent or Dometic.
The electrical fuse of the power
supply is too low.
Check the electrical fuse of
the power supply.
Remote control
does not regis-
ter.
The remote control is not pointing
towards the air outlet unit display.
Point the remote control
towards the air outlet unit
display.
The batteries in the remote control
are empty.
Note: The display of the remote
control will still be bright even if the
batteries are low.
Replace the batteries in the
remote control.
Problem Cause Remedy
Harrier-Lite_OPM.book Seite 24 Montag, 27. April 2020 3:25 15