Manual

AU
IBIS4 Troubleshooting
23
Not heating well The roof air conditioner is not set to
heating.
Set the roof air conditioner to
heating.
The ambient temperature is below
–2 °C.
The roof air conditioner is
designed for best operation at
ambient temperatures above
–2 °C.
The temperature set is lower than the
room temperature.
Select a higher temperature.
One of the temperature sensors is
defective.
Contact an authorised service
agent or Dometic.
The evaporator fan is damaged.
The condenser fan is damaged.
Low air output The air intake grilles are blocked or
obstructed.
Remove any leaves and other
dirt from the ventilation grilles
of the roof air conditioner.
The fan is defective. Contact an authorised service
agent or Dometic.
Water enters the
vehicle.
The condensation water drainage
openings are clogged up.
Clean the drainage openings
for condensation water.
The seals are damaged. Contact an authorised service
agent or Dometic.
Roof air
conditioner does
not switch on.
No supply voltage (240 V AC)
connected.
Check the power supply.
The voltage is too low (under
200 V AC).
Contact an authorised service
agent or Dometic.
The voltage converter is defective.
One of the temperature sensors is
defective.
The electrical fuse of the power
supply is too low.
Check the electrical fuse of
the power supply.
Roof air
conditioner does
not switch off.
One of the temperature sensors is
defective.
Contact an authorised service
agent or Dometic.
The electrical fuse of the power
supply is too low.
Check the electrical fuse of
the power supply.
Problem Cause Remedy
IBIS4--O.book Seite 23 Montag, 5. November 2018 7:56 19