L-2230 Specifications
6.0 Elite Controls • Specifications
Set Point Operating Range ............................................................ 65°F to 85°F (18.3°C to 29.4°C)
Ambient Temperature Operating Range Displayed ......................... 5°F to 150°F (-15°C to 65.6°C)
Sensor Accuracy ............................................................................. ± 2°F @ 77°F (±1.1°C @ 25°C)
Low Voltage Limit 115 Volt Units........................................................................................... 75 VAC
Low Voltage Limit 220 Volt Units......................................................................................... 175 VAC
Low Voltage Processor Reset ............................................................................................... 50 VAC
Line Voltage .................................................................................................. 115 Through 240 VAC
Frequency ...................................................................................................................... 50 or 60 Hz
Fan Output ................................................................ 6 Amps @ 115 VAC and 6 Amps @ 230 VAC
Valve Output ........................................................................................... 1/4 Amps @ 115/230 VAC
Pump Output ............................................................... 1/4 HP @ 115 VAC and 1/2 HP @ 230 VAC
Compressor Output ........................................................... 1 HP @ 115 VAC and 2 HP @ 230 VAC
Minimum Operating Temperature ................................................................................ 0°F (-17.8°C)
Maximum Ambient Operating Temperature .............................................................. 180°F (82.2°C)
Maximum Rh Conditions ................................................................................ 99% Non Condensing
Power Consumption ............................................................................................ Less Than 5 Watts
Electric Heater Output ........................................... 30 Amps @ 115 VAC and 20 Amps @ 230 VAC
Dimensions
Display Panel .............................................................................4.41" (11.20 cm) X 2.96" (7.52 cm)
Panel Cut Out ......................................................... 3
5
/
16
" (3.31"/8.41 cm) X 2
3
/
16
"" (2.19"/5.56 cm)
Bezel Size ..................................................................................4.85" (12.32 cm) X 3.25" (8.26 cm)
Cable Lengths
Display Cable Self Contained............................................................................ 15' (4.6m) Standard
Display Cable Central System........................................................................... 30' (9.1m) Standard
Alternate Air Sensor ............................................................................................ 7' (2.1m) Standard
Alternate Air Sensor Central System................................................................ 30' (9.1m) Standard
Outside Air Sensor ............................................................................................ 15' (4.6m) Standard
All custom cable lengths supplied in standard 5' (1.5m) increments............. 75' (22.9m) Maximum
NOTES: Maximum length of display and sensor cables is 75 feet (22.9m). The outside air sensor
and alternate air sensors are optional items and are not included with the standard control package.
System Inputs
Ambient or Inside Air Temperature ................................................................................................. 1
High Freon Pressure ....................................................................................................................... 1
Low Freon Pressure ........................................................................................................................ 1
Alternate Inside Air Temperature Sensor (Optional) ....................................................................... 1
Outside Air Temperature Sensor (Optional).................................................................................... 1