Checking the LP gas pressure
The LP gas pressure should be checked and the main regulator
readjusted if pressure is incorrect. The correct operating pres-
sure is 11 inches of water column. Measure the LP gas pressure
at the test port, just ahead of the burner jet.
MAINTENANCE & SERVICE
Always keep the food compartment and the freezer clean. If the refrigerator will not be in operation for a period of weeks it should
be emptied, defrosted, cleaned and the doors left ajar, see
STORAGE PROCEDURE / WINTERIZING THE REFRIGERATOR
.
Periodic inspection, cleaning and maintenance of the refrigerator is recommended. Follow the simple checks below:
Make sure the area behind the refrigerator is clear and free from combustible material, gasoline and other fl ammable
vapors or liquids.
Dust off the coils on the back of the refrigerator (use a soft brisled brush).
Make sure the upper and lower vents are free from any obstructions.
Check the burner fl ame for proper appearance. (The fl ame should be light blue.)
At least once a year, a qualifi ed service technician should inspect the connections, the control system, the LP gas pressure and
fl ue baffl e, see
PERIODIC MAINTENANCE
.
•
•
•
•
PERIODIC MAINTENANCE
Checking the connections
Check all connections in the LP gas system (at the
back of the refrigerator) for gas leaks. The LP gas
supply must be turned on.
Apply a non-corrosive bubble solution to all LP gas
connections. The appearance of bubbles indicates a
leak and should be repaired
immediately
by a quali-
fi ed serviceman.
DO NOT use a fl ame to check for gas leaks!
1.
2.
BURNER TUBE .
SPARK ELECTRODE
BURNER JET
BURNER MOUNTING
SCREWS
PRESSURE TEST PORT
MANUAL SHUT OFF VALVE
Shown in open position
INLET FITTING
SOLENOID VALVE
Gas equipment assembly
WARNING
!